Mounting/Dismounting Modules; Mounting/Dismounting Controller/Sockets - Honeywell CENTRA LINE LION CLLIONLC01 Installation & Commissioning Instructions

Table of Contents

Advertisement

Mounting/Dismounting Modules

Mounting/Dismounting Modules
WARNING
Risk of electric shock or equipment damage!
Do not touch any live parts in the cabinet.
Disconnect the power supply before you start to install
the LION System.
More than one disconnect switch may be required to de-
energize the system.
Do not reconnect the power supply until you have
completed the installation.
Note
The terminal socket of each pluggable I/O module can be
mounted and wired before inserting and locking the
corresponding electronic module.
1
71 COM a
COM a
72 COM b
COM b
73
24V~
24V~
74 24V 0
~
24V 0
~
LON
C-BUS
RESET
PC/HMI
1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
!
Modem
11
S1
S2
1
9.6k
all
21
12
8
5
Panel
2
76k
mid
LON
V
13
9
6
3
AUX
76k
end
C-Bus
I/O Bus
14
10
7
Rx Tx
4
GND
C-Bus
C-Bus
Power/
LON
in
out
Alarm
9
4
S1
S2
71 COM a
4
72 COM b
73
24V~
74 24V 0
~
1
3
1
2
0
100
A
A
A
AUTO
A
!
21
11
21
31
41
51
61
61
V
12
22
32
42
52
62
62
AUX
13
23
33
43
53
63 63
GND
14
24
34
44
54
64
25
9
Fig. 14
CLLIONLC01 and I/O modules mounted on
multiple DIN rails
Legend
1
CLLIONLC01
2
Swivel label holder
3
Cable connection
rd
4
Stopper (from 3
-party supplier)
5
Bridge connectors
6
Auxiliary terminal package
EN1Z-0921GE51 R0709
2
1:ABCDFERTAQWESDERT1
1:ABCDFERTAQWESDERT1
2:ABCDFERTAQWESDERT2
2:ABCDFERTAQWESDERT2
3:ABCDFERTAQWESDERT3
3:ABCDFERTAQWESDERT3
4:ABCDFERTAQWESDERT4
4:ABCDFERTAQWESDERT4
5:ABCDFERTAQWESDERT5
5:ABCDFERTAQWESDERT5
6:ABCDFERTAQWESDERT6
6:ABCDFERTAQWESDERT6
7:ABCDFERTAQWESDERT7
7:ABCDFERTAQWESDERT7
8:ABCDFERTAQWESDERT8
8:ABCDFERTAQWESDERT8
2
4
5
6
7
8
1 2 3 4 5 6 7 8 9 10 11 12
3
!
!
22
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
9
10
11
12
AI/AO
BI
GND
GND
10
11
12
13
14
15
16
17
18
25
26
13
14
15
16
17
18
19
20
21
22
23
24
25
26
5
S1
S2
S1
S2
4
4
2
4
5
6
7
8
1
2
4
5
6
3
3
--1
0
100
--0
A
A
A
A
A
A
A
AUTO
--AUTO
!
!
22
1
2
3
4
5
6
7
8
11
21
31
41
51
61
61
AI/AO
12
22
32
42
52
62
62
13
23
33
43
53
63 63
GND
10
11
12
13
14
15
16
17
18
25
26
14
24
34
44
54
64
25
6

Mounting/Dismounting Controller/Sockets

Mounting Sockets
Notes
• When using both Panel Bus and L
modules in a LION System, group both Panel Bus
modules (light gray) and L
(dark gray), e.g., on different rails.
• Up to 10 Panel Bus I/O modules can be mounted to one
side of the controller. In total, up to 16 Panel Bus
I/O modules can be mounted to one controller.
• The CLLIONLC01 and the mixed Panel Bus I/O module
are mounted on the DIN rail in the same way as a
terminal socket.
PANEL
PANEL
BUS
BUS
I/O
max. 10
3
Fig. 15
Max. number of Panel Bus I/O modules
LonWorks
LonWorks
BUS I/O
BUS I/O
max. 10
Fig. 16
Max. number of L
power supply via CLLIONLC01
18
W
ON
ORKS
W
Bus I/O modules
ON
ORKS
PANEL
CLLIONLC01
BUS
I/O
I/O
max. 16
LonWorks
CLLIONLC01
BUS I/O
max. 20
W
Bus I/O modules with
ON
ORKS
LION System
Bus I/O
PANEL
BUS
I/O
max. 10
LonWorks
LonWorks
BUS
BUS I/O
I/O
max. 10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents