Honeywell CP-UL1012S Installation Instructions Manual

Honeywell CP-UL1012S Installation Instructions Manual

Advertisement

Quick Links

ComfortPoint Programmable Lon,
VAV/Unitary Controllers
Controller
Programmable
Model
Type
CP-UL1012S
Unitary
CP-UL4024S
Unitary
CP-UL6438S
Unitary
CP-VL0000AS
VAV
CP-VL4022AS
VAV
CP-VL4024NS
VAV
CP-VL6436AS
VAV
CP-VL6438NS
VAV
a
One Universal Input (UI-1*) is user selectable as a fast digital pulse meter.
Each controller communicates via the 78 kbps Echelon® L
L
M
® compliant.
ON
ARK
Controllers are field-mountable to either a panel or a DIN rail.
Table 1. Controller configurations.
Universal
Digital
Inputs
Inputs
(UI)
(DI)
0
a
1
0
a
4
6
4
0
0
0
a
4
a
0
4
6
4
6
4
W
ON
ORKS
INSTALLATION INSTRUCTIONS
PRODUCT DESCRIPTION
The CP-UL1012S, CP-UL4024S, CP-UL6438S,
CP-VL0000AS, CP-VL4022AS, CP-VL4024NS,
CP-VL6436AS, and CP-VL6438NS controllers are part of the
Excel 10 product line family. The eight controllers are Free
Topology Transceiver (FTT) L
designed to control HVAC equipment. These controllers
provide many options and advanced system features that
allow state-of-the-art commercial building control. Each
controller is programmable and configurable through software.
These controllers are for use in VAV (Variable Air Volume) and
Unitary HVAC control applications. Each controller contains a
host micro controller to run the main HVAC application and a
second micro controller for L
tions. Each controller has flexible, universal inputs for external
sensors, digital inputs, and a combination of analog and digital
Triac outputs. The eight models are described in Table 1. The
photo to the left is the model CP-VL6436AS, which includes
the actuator.
Analog
Digital
Outputs
Outputs
(AO)
(DO)
1
2
2
4
3
8
0
0
2
2
2
4
3
6
3
8
® Network, using the FTT-10A L
®
M
-compliant devices
ON
ARK
W
® network communica-
ON
ORKS
Velocity
Pressure
Series 60
Sensor
Floating
(Microbridge)
Actuator
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
NO
YES
YES
YES
NO
W
® interface, and is
ON
ORKS
62-0288—03

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell CP-UL1012S

  • Page 1 ComfortPoint Programmable Lon, VAV/Unitary Controllers INSTALLATION INSTRUCTIONS PRODUCT DESCRIPTION The CP-UL1012S, CP-UL4024S, CP-UL6438S, CP-VL0000AS, CP-VL4022AS, CP-VL4024NS, CP-VL6436AS, and CP-VL6438NS controllers are part of the Excel 10 product line family. The eight controllers are Free ® Topology Transceiver (FTT) L -compliant devices designed to control HVAC equipment.
  • Page 2: Specifications

    Minimum 32 F (0 C); Maximum 122 F (50 C) length is 1-9/16 in. (40 mm). Unitary Operating & Storage Temperature Ambient Rating (models CP-UL1012S, CP-UL4024S, and CP-UL6438S): The two mechanical end-limit set screws control the amount Minimum -40 F (-40 C); Maximum 150 F (65.5 C) of rotation from 12°...
  • Page 3 COMFORTPOINT PROGRAMMABLE LON, VAV/UNITARY CONTROLLERS Mounting Actuator onto Damper Shaft (CP-VL0000AS, CP-VL4022AS, and CP-VL6436AS ) DAMPER The unit is shipped with the actuator set to rotate open in the clockwise (CW) direction to a full 95 degrees. The extra 5 degrees ensures a full opening range for a 90 degree damper.
  • Page 4: Mount Controller

    Fig. 5. Panel mounting — controller dimensions in inches 2 2 2 2 2 2 2 2 3 5-3/4 (mm) for CP-UL1012S, CP-UL4024S, and CP-VL4024NS 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8 0...
  • Page 5 Never remove by pulling at an angle. BOTTOM FLEX AIR FLOW M16815 CONNECTORS PICKUP CONNECTOR Fig. 8. Controller DIN rail mounting (models CP-UL1012S, TUBING CP-UL4024S, CP-UL6438S, CP-VL4024NS, and CP-VL6438NS). RESTRICTOR RESTRICTOR PORT PORT Δ...
  • Page 6 COMFORTPOINT PROGRAMMABLE LON, VAV/UNITARY CONTROLLERS Wiring IMPORTANT If the controller is used on Heating and Cooling All wiring must comply with applicable electrical codes and Equipment (UL 1995, U.S. only) and the ordinances, or as specified on installation wiring diagrams. transformer primary power is more than 150 volts, Controller wiring is terminated to the screw terminal blocks connect terminal 2, (the 24 Vac common [24 VAC...
  • Page 7: Wiring Method

    COMFORTPOINT PROGRAMMABLE LON, VAV/UNITARY CONTROLLERS NOTE: Controller configurations are not necessarily limited to three devices, but the total power draw, including accessories, cannot exceed 100 VA when powered by the same transformer (U.S. only). For power wiring recommendations, see “Wiring” on page 6. Δ...
  • Page 8 ® and the Niagara framework logo are registered trademarks of Tridium, Inc. IAGARA RAMEWORK By using this Honeywell literature, you agree that Honeywell will have no liability for any damages arising out of your use or modification to, the literature. You will defend and indemnify Honeywell, its affiliates and...

This manual is also suitable for:

Cp-ul4024sCp-ul6438sCp-vl0000asCp-vl4022asCp-vl4024nsCp-vl6436as ... Show all

Table of Contents