Honeywell CentraLine LYNX LON CLLYUL1012S Product Data

Programmable vav/unitary controllers

Advertisement

Quick Links

LYNX LON Programmable
VAV/Unitary Controllers
model
type
CLLYUL1012S
unitary
CLLYUL4024S
unitary
CLLYUL6438S
unitary
CLLYVL0000AS
VAV
CLLYVL4022AS
VAV
CLLYVL4024NS
VAV
CLLYVL6436AS
VAV
CLLYVL6438NS
VAV
*One Universal Input (UI-1) is user-selectable as a fast digital pulse meter.
All eight LYNX controllers communicate via the 78 kbps Echelon® L
interface, and are L
M
®-compliant.
ON
ARK
The LYNX controllers are field-mountable to either a panel or a DIN rail.
Copyright © 2015 Honeywell GmbH ● All Rights Reserved
Product Data
Table 1. Controller configurations
Universal
Digital
Inputs (UI)
Inputs (DI)
1*
0
4*
0
6
4
0
0
4*
0
4*
0
6
4
6
4
GENERAL
The LYNX controllers CLLYUL1012S, CLLYUL4024S,
CLLYUL6438S, CLLYVL0000AS, CLLYVL4022AS,
CLLYVL4024NS, CLLYVL6436AS, and CLLYVL6438NS are
part of the LYNX family. They are Free Topology Transceiver
(FTT) L
M
®-compliant devices designed to control
ON
ARK
HVAC equipment.
LYNX controllers provide many options and advanced system
features that allow state-of-the-art commercial building
control. Each LYNX controller is programmable and con-
figurable through software.
LYNX controllers are designed for use in VAV (Variable Air
Volume) and Unitary HVAC control applications. Each con-
troller contains a host microcontroller to run the main HVAC
application and a second microcontroller for L
network communications. Each controller has flexible, uni-
versal inputs for external sensors, digital inputs, and a mix of
analog and digital triac outputs (see Table 1). The accom-
panying image is of the model CLLYVL6436AS, which
includes an actuator.
Analog Out-
Digital Out-
puts (AO)
puts (DO)
1
2
2
4
3
8
0
0
2
2
2
4
3
6
3
8
W
® Network, using the FTT-10A L
ON
ORKS
W
®
ON
ORKS
velocity pressure
floating
sensor
actuator
(Microbridge)
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
NO
YES
YES
YES
NO
W
®
ON
ORKS
EN0Z-0957GE51 R0615

Advertisement

loading

Summary of Contents for Honeywell CentraLine LYNX LON CLLYUL1012S

  • Page 1 All eight LYNX controllers communicate via the 78 kbps Echelon® L ® Network, using the FTT-10A L ® ORKS ORKS interface, and are L ®-compliant. The LYNX controllers are field-mountable to either a panel or a DIN rail. Copyright © 2015 Honeywell GmbH ● All Rights Reserved EN0Z-0957GE51 R0615...
  • Page 2: Technical Data

    LYNX LON PROGRAMMABLE, VAV/UNITARY CONTROLLERS – PRODUCT DATA TECHNICAL DATA ANALOG OUTPUT (AO) CIRCUIT GENERAL SPECIFICATIONS Configuration for current / All 3 analog outputs can be individually Rated voltage: 20 … 30 VAC; 50/60 Hz voltage: configured for current or voltage. Power consumption: 100 VA for controller and all connected Configuration as digital...
  • Page 3 LYNX LON PROGRAMMABLE, VAV/UNITARY CONTROLLERS – PRODUCT DATA IMPORTANT IMPORTANT Avoid mounting in areas where acid fumes or other deteriorating vapors can attack the metal parts of the Determine the damper rotation and opening angle prior to controller, or in areas where escaping gas or other installation.
  • Page 4 LYNX LON PROGRAMMABLE, VAV/UNITARY CONTROLLERS – PRODUCT DATA b) Using the DECLUTCH button, rotate the universal TYPE A DAMPER shaft adapter fully CCW. c) Mount the actuator to the damper box and shaft. d) Tighten the two bolts on the centering clamp (8 mm FLOW wrench;...
  • Page 5: Panel Mounting

    LYNX LON PROGRAMMABLE, VAV/UNITARY CONTROLLERS – PRODUCT DATA 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 4 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 1 1 1 1 1 1 1 1 2 1 2 3 4 5 6 7 8 9 0 CLLYVL6438NS...
  • Page 6 LYNX LON PROGRAMMABLE, VAV/UNITARY CONTROLLERS – PRODUCT DATA IMPORTANT NOTE 3: Use caution when removing tubing from a con- nector. Always pull straight away from the con- To remove the controller from the DIN rail, perform the nector or use diagonal cutters to cut the edge of following: the tubing attached to the connector.
  • Page 7 LYNX LON PROGRAMMABLE, VAV/UNITARY CONTROLLERS – PRODUCT DATA the controller, such as equipment actuators and various IMPORTANT contactors and transducers. Power must be OFF prior to connecting to or removing connections from the 24 VAC power (24 VAC/24 VAC COM), earth ground (EGND), and 20 Vdc power IMPORTANT (20 Vdc) terminals.
  • Page 8 LYNX LON PROGRAMMABLE, VAV/UNITARY CONTROLLERS – PRODUCT DATA IMPORTANT In noisy (high EMI) environments, avoid wire runs parallel to noisy power cables, motor control centers, or lines containing lighting dimmer switches. Keep at lest 76 mm of separation between noisy lines and the CONNECT POWER TO CONNECT POWER TO CONNECT POWER TO...
  • Page 9 LYNX LON PROGRAMMABLE, VAV/UNITARY CONTROLLERS – PRODUCT DATA Wiring Details Table 3. Description of wiring terminals (CLLYUL6438S, CLLYVL6436AS, and CLLYVL6438NS) Each controller is shipped with the digital outputs, which TERMINAL LABEL CONNECTION switch the 24 VAC to the load (high side). INPUT POWER &...
  • Page 10 LYNX LON PROGRAMMABLE, VAV/UNITARY CONTROLLERS – PRODUCT DATA implement (such as a pencil with the lead broken off) Table 4. Description of wiring terminals (CLLYUL1012S, to press the pin. Using a metal object can damage the CLLYUL4024S, CLLYVL0000AS, CLLYVL4022AS, and controller's circuitry.
  • Page 11 LYNX LON PROGRAMMABLE, VAV/UNITARY CONTROLLERS – PRODUCT DATA  Typical controller wiring for PWM reheat and PWM CLCM4T111 WALL MODULE peripheral heat valve actuator (see Fig. 17). BYPASS SET-POINT  Typical controller wiring for AHU application (see Fig. 18). SENSOR Typical controller wiring for 4…20 mA enthalpy sensors ...
  • Page 12 LYNX LON PROGRAMMABLE, VAV/UNITARY CONTROLLERS – PRODUCT DATA OUTDOOR ENTHALPY CLCM4T111 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 4 WALL MODULE 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 RETURN ENTHALPY BYPASS SET-POINT...
  • Page 13 LYNX LON PROGRAMMABLE, VAV/UNITARY CONTROLLERS – PRODUCT DATA 2- OR 3-WAY CHILLER 2- OR 3-WAY HOTWATER/ CLCM4T111 WALL MODULE CLCM4T111 WATER VALVE STEAM VALVE OUTDOOR ENTHALPY WALL MODULE BYPASS SERIES 70 SERIES 70 BYPASS SET-POINT VALVE ACTUATOR VALVE ACTUATOR SET-POINT SENSOR SENSOR RETURN ENTHALPY...
  • Page 14 LYNX LON PROGRAMMABLE, VAV/UNITARY CONTROLLERS – PRODUCT DATA Verify Termination Module Placement (Multiple Controllers, Only) 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 4 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 The installation wiring diagrams should indicate the locations for 209541B termination module(s).
  • Page 15: Controller Replacement

    LYNX LON PROGRAMMABLE, VAV/UNITARY CONTROLLERS – PRODUCT DATA The LED on the front of the controller provides a visual Terminal Block Removal indication of the status of the device. When the controller To simplify controller replacement, all terminal blocks are receives power, the LED appears in one of the following designed to be removed with the wiring connections intact allowable states, as described in Table 5.
  • Page 16 2) Rotate the top of the controller outwards to release the bottom flex connectors (see Fig. 8). Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Rolle, Z.A. La Pièce 16, Switzerland by its Authorized Representative: CentraLine Honeywell GmbH Böblinger Strasse 17...