Removing The Electronics Intake Fan (#7) - Christie M Series Service Manual

Hide thumbs Also See for M Series:
Table of Contents

Advertisement

9. To re-install, follow these steps in reverse order.

Removing the electronics intake fan (#7)

Fan #7 is located inside the filter bay on the outside of the card cage.
Estimated replacement time: 18 minutes.
1. Remove the top cover (on page 45).
2. Remove the card cage lid (on page 59).
3. Remove the bridge (on page 60).
4. Remove the card cage (on page 61).
5. Remove the fan by removing the four isolator pads in each corner.
To remove the fan, the card cage must be removed. The backs of the isolator pads are not
accessible after removing the card cage. Almost the entire inside of the card cage must be
removed to access them. Replacement isolator pads are part of the service kit.
The proper orientation of this fan is with the label on the fan hub facing inward towards the
card cage. An airflow indicator arrow on the fan must be pointing inward towards the card
cage.
M Series Service Guide
020-100551-11 Rev. 1 (01-2019)
Copyright
2019 Christie Digital Systems USA, Inc. All rights reserved.
©
Ventilation and cooling
53

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds+6k-mDs+10k-mDs+14k-mHd6k-mWu7k-mWu12k-m ... Show all