WAGO-I/O-SYSTEM 750
DeviceNet
Configuration / Parametering with the Object Model
RELEASE_
PIO
BK_DO_FA
specific
get/set
ULT_REAC
TION_ON_
RELEASE_
COS
specific
get/set
BK_DO_FA
ULT_REAC
TION_ON_
RELEASE_
ST
specific
get/set
BK_static_
ana-
log_digital_i
nput_mappi
ng
specific
get/set
BK_static_
ana-
log_digital_
out-
put_mappin
g
specific
get/set
BK_specific
_coupler_b
ehavior
BK_revisio
specific
get/set
n_setting
specific
get
BK_LED_ER
R_CODE
specific
get
BK_LED_ER
R_ARG
specific
get
BK_DIAG_V
ALUE
specific
get/set
BK_FIXED_P
ROD_SIZE
specific
get/set
BK_FIXED_C
ONS_SIZE
1: Process the coupler fault reaction
USINT
Defines the behavior after de allocation the
Change of State and Cyclic I/O Connection
0: (default) do nothing
1: Process the coupler fault reaction
USINT
Defines the behavior after de allocation the
strobed Connection
0: (default) do nothing
1: Process the coupler fault reaction
UINT
Defines how to calculate the values for the
number of analog and digital input bits.
0000: All bits are digital
0016: One word is analog remaining bits are
digital
0032: Two words are analog remaining bits
are digital
...
0xFFFF: All bits are handled like module type
(default)
UINT
Defines how to calculate the values for the
number of analog and digital input bits.
0000: All bits are digital
0016: One word is analog remaining bits are
digital
0032: Two words are analog remaining bits
are digital
...
0xFFFF: All bits are handled like module type
(default)
(If the number of analog bits exceeds the size
of the process image all bits are mapped to
analog bits.
UINT
Defines the couplers functionality.
0xFFFF: All possible functions are enabled.
(resetting a bit to 0 disables the assigned
functionality).
It is only possible to reduce the functionality.
Resetting to „1" is ignored.
UINT
Defines the couplers major and minor revision
attribute.
0xFFFF: The major and minor revison Attrib-
utes are set by the firmware.
(This is the default behavior).
0x??00: The minor revison is set to 0.
0x03??: The mjor revison is set to 3.
All other values are valid to.
UINT
Defines the Error Code, displayed by the
blink code of the I/O LED.
UINT
Defines the Error Argument, displayed by the
blink code of the I/O LED.
UINT
Defines the Diagnostic information, supplied
by the IO Module. This attribute must be read
out before attribute 6 of this class. Only if
attribute 6 contains valid data, it contains also
valid data.
USIN
Fixed width of the ProduceConnectionSize
T
(input data) 0xFFFF(default): ProduceCon-
nectionSize corresponds to the data width of
the connected input modules 0 – 32 (
PI_LIMIT ): Fixed width of the ProduceCon-
nectionSize, independent of the input mod-
ules. PI_LIMIT – 0xFFFE: These values
These values cannot be set and led to fault
messages. The adjusted value become only on
valid with next switching.
USIN
Fixed width of the ConsumedConnectionSize
T