WAGO I/O System 750 Series Manual page 85

Modular i/o system
Hide thumbs Also See for I/O System 750 Series:
Table of Contents

Advertisement

Instance 14:
Attribute
ID
3
Instance 15:
Attribute
ID
3
Services:
Service Code
0x0E
0x10
4.6.2.1.6 Connection Object (0x05):
Instance 0:
Attribute
ID
1
Description of the instances:
Instance ID
1
2
3
4
5
WAGO-I/O-SYSTEM 750
DeviceNet
Configuration / Parametering with the Object Model
Used in
Access
Name
buscoupler
rule
dep. on kind
get
Process
of connected
image +
modules
Error
Code +
Error
Argument
+ Status
Used in
Access
Name
buscoupler
rule
dep. on kind
get
Status
of connected
+ first zero
modules
byte ('0')
+ second
zero byte
('0')
+ third
zero byte
('0')
+ Process
image
Service Name
Get_Attribute_Single
Set_Attribute_Single
Used in
Access
Name
buscoupler
rule
required
get
Revision
Description
References the Explicit Messaging Connection into the Server
References the Poll I/O Connection
References Bit-Strobe I/O Connection
References the Slave´s Change of State or Cyclic I/O Connection
Reserved for „Reserved Identifier", Message ID 1
Data type
Description
Array of
process image, collection of all
Byte
analog modules process input data
plus Error Code (Cl. 100/Inst. 1/
Attr. 45)
plus Error Argument (Cl. 100/Inst.
1/ Attr. 46)
plus Status (Cl. 100/Inst. 1/Attr. 5)
Data type
Description
Array of
Status (Cl. 100/Inst. 1/Attr. 5)
Byte
plus three bytes, which are always
zero plus analog and digital input
data
Description
Used to read a DeviceNet Object attribute value
Used to modify a DeviceNet object attribute value
Data type
Description
UINT
Revision of the Connection
Object, Range 1-65535, class
definition upon which the im-
plementation is based.
DeviceNet
• 85
Value
Value
Default
Value
0x0001

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

750-346