13
14
15
16
17
Services:
Service Code
0x0E
0x10
0x05
The instances are not available if the connection is in state „non existent".
I/O Connection Object State
Get_Atribute/
Set_Attribute/
Apply_Attributes
Fig. 4-1: Status of I/O Connection Objects
WAGO-I/O-SYSTEM 750
DeviceNet
Configuration / Parametering with the Object Model
required
get
required
get/set
required
get
required
get
required
get/set
Non-Existent
Create
Configuring
Apply_Atributes
Get_Atribute/
Established
Set_Attribute/
Apply_Attributes/
Reset/Message
Produced/Consumed
Reset
Delete
Timed Out
ut_action
pro-
UINT
duced_con
nec-
tion_path_
length
pro-
Array of
duced_con
USINT
nec-
tion_path
con-
UINT
sumed_co
nnec-
tion_path_
length
con-
Array of
sumed_co
USINT
nnec-
tion_path
produc-
USINT
tion_inhibi
t_time
Service Name
Description
Get_Attribute_Single
Used to read a DeviceNet Object attribute value
Set_Attribute_Single
Used to modify a DeviceNet object attribute value
Reset
Restores connection default values.
Delete from any state
Apply_Atributes
Inactivity/Watchdog
Timeout & watchdog_timeout_action =
Transition to Time Out
DeviceNet
number of Bytes in pro-
duced_connection_path attribute
specifies the application objects which data is
to be produced by this connection object
number of Bytes in con-
sumed_connection_path attribute
specifies the application objects that are to
receive the data consumed by this connection
object
defines minimum time between new data
production
Get_Atribute/Set_Attribute
Apply Atributes
Waiting for
Connection ID
• 89
g012546x