5.2.2.2 Remove Cables Between Gateway Switches
You must remove the cables connected in ports 4A, 4B, 5A, 5B, 6A, and 6B between
gateway switches in both the racks.
5.2.2.3 Connect Each Leaf Switch to the Spine Switch
Table 5-2
GW) to the spine switch (NM2-36P) in the Exalogic machine rack. The 3-meter cables
are bundled with the Exalogic machine. You should connect leaf switches to the spine
switches in each of the Exalogic machine full racks that will be connected.
Table 5-2
Cable Coming from
Slot
U26
U26
U26
U26
U24
U24
U24
U24
U23
U23
U23
U23
U16
U16
U16
U16
lists the 3-meter cables that should be used to connect leaf switches (NM2-
Connect 3-Meter Cables from Each Leaf Switch to the Spine Switch
Port
0A
0B
1A
1B
0A
0B
1A
1B
0A
0B
1A
1B
0A
0B
1A
1B
Note:
Make the connections between leaf switches and spine switch as shown in
Table 5-2
for both Exalogic machines.
Connecting Two Exalogic Machine Full Racks Together
Connecting to Slot
Port
U1
1A
U1
1B
U1
2A
U1
2B
U1
3A
U1
3B
U1
4A
U1
4B
U1
5A
U1
5B
U1
6A
U1
6B
U1
7A
U1
7B
U1
8A
U1
8B
Chapter 5
Length
3 meter
3 meter
3 meter
3 meter
3 meter
3 meter
3 meter
3 meter
3 meter
3 meter
3 meter
3 meter
3 meter
3 meter
3 meter
3 meter
5-4