Oracle Exalogic EL X2-2 Multirack Cabling Manual page 41

Elastic cloud
Table of Contents

Advertisement

Connecting an Exalogic Machine Quarter Rack and an Exadata Database Machine Quarter Rack
Table 6-7
(Cont.) Cross-Connections Between Exalogic Machine Quarter Rack
and Exadata Database Machine Quarter Rack
Exadata Database Machine
Leaf Switch
R2-U24
R2-U24
R2-U20
R2-U20
R2-U20
R2-U20
Note:
R2 in
Table 6-7
indicates an Exadata Database Machine full rack that is being
connected to an Exalogic machine full rack (R1).
In
Table
6-7, ports 1A and 1B are horizontal connections across the two machine
racks being connected (top leaf switch to top leaf switch). Ports 2A and 2B are the
cross connections between the racks (top leaf switch to bottom leaf switch).
You require only 8 cables to connect an Exalogic machine quarter rack and an
Exadata Database Machine. If these systems are side by side, you can use the 5-
meter Infiniband cables included in the spares kit to complete these connections.
For network connectivity diagrams of other Exalogic-to-Exadata scenarios, see
Multirack Cabling Diagrams for Exalogic-to-Exadata Scenarios
Exalogic Machine
Port
Leaf Switch
2A
R1-U16
2B
R1-U16
1A
R1-U16
1B
R1-U16
2A
R1-U23
2B
R1-U23
Chapter 6
Port
2A
2B
1A
1B
2A
2B
.
6-9

Advertisement