Technical Specifications Connection Box - Siemens SIMATIC Mobile Client900RFN Operating Instructions Manual

Table of Contents

Advertisement

Software
Operating system
SMM firmware,
no license required
10.4.2

Technical specifications Connection Box

Weight without packaging
Housing (width × height × depth)
Electrical system
The specifications apply for the connection box with connected device.
Nominal voltage
Range, permissible
Transients, maximum permissible
Time between two transients, minimum
Power consumption, typically
Constant current, maximum
Inrush current I
Power consumption, with non-artic HMI device
Power consumption, with Artic HMI device
Inrush current
Overvoltage category
Fuse
Current load PLC-accompanying signals
Recovery time
Interruption time of power supply, maximum
Degree of protection
Protection class
Mobile Client900RXA
Operating Instructions, 07/2015, A5E36360099-AA
Linux
FreeRTOS V5.0.3,
http://www.freertos.org/
TI Driver Library, Stellaris Peripheral Driver Library, version 6852,
http://www.ti.com/tool/sw-lm3s
t
2
Technical specifications
Approx. 280 g
70 mm × 74 mm × 50 mm
+24 V DC
DC +19.2 ... +28.8 V (–20 ... +20%)
35 V, 500 ms
50 s
Approx. 700 mA
Approx. 1400 mA
Approx. 0.6 A
s
2
16 W, 700 mA at 24 V DC
34 W, 1400 mA at 24 V DC
≤ 1.5 A, duration 1 ms during commissioning
≤ 3.2 A, duration 1 ms during switch-on operation
II
2 × 2 A glass tube fuse, 5 × 20 mm, UL 248
Not available
≥ 1 s
10 ms in accordance with EN 61131-2
IP20
IP65 with correct exterior mounting to control
cabinet wall and with connecting cable fitted
III to EN 61131-2
10.4 Specifications
145