Connecting The Mobile Client - Siemens SIMATIC Mobile Client900RFN Operating Instructions Manual

Table of Contents

Advertisement

3.3.2

Connecting the mobile client

The connecting cable can be connected to the connection box using a female connector at
the device and a male connector at the connection box. A red dot helps you align the
connector for connection.
Requirement
● The connection box is connected and supplied with power.
Procedure
Plug in connector
1. Align the red dot on the connecting cable connector with the red dot on the connection
box socket.
2. Insert the connector into the socket and push until it clicks into place.
3. Swing down the locking clip until it slots into place on the connector.
4. Align the red dot on the connecting cable connector with the red dot on the mobile client
socket.
5. Insert the connector into the socket and push until it clicks into place.
6. Swing down the locking clip until it slots into place on the connector.
Incorrectly plugged in connectors cause malfunctions
If the connecting cable connector is not positioned correctly at the connection box as well
as the device, this will disrupt power supply, data transfer and shielding. This can result in
machine and system malfunctions.
• Make sure that the mark on the connector (red dot) matches that on the socket.
• Make sure that the connector is fully inserted.
• Make sure that the connector is secured with the locking clip and that the locking clip is
Mobile Client900RXA
Operating Instructions, 07/2015, A5E36360099-AA
CAUTION
securely positioned against the connector.
Installing and connecting the device
3.3 Connecting the device
41