Parameter Lists
®
VLT
Micro Drive FC 51 Programming Guide

5.1.11 6-** Analog In/Out

Parameter
Parameter Description
Default Value
Number
6-00
Live Zero Timeout Time
10 s
6-01
Live Zero TimeoutFunction
[0] Off
6-10
Terminal 53 Low Voltage
0.07 V
6-11
Terminal 53 High Voltage
10 V
6-12
Terminal 53 Low Current
0.14 mA
6-13
Terminal 53 High Current
20 mA
Terminal 53 Low Ref./Feedb.
6-14
Value
0
Terminal 53 High Ref./Feedb.
6-15
Value
50
6-16
Terminal 53 Filter Time Constant
0.01 s
6-19
Terminal 53 mode
[0] Voltage mode
6-22
Terminal 60 Low Current
0.14 mA
6-23
Terminal 60 High Current
20 mA
Terminal 60 Low Ref./Feedb.
6-24
Value
0
Terminal 60 High Ref./Feedb.
6-25
Value
50
6-26
Terminal 60 Filter Time Constant
0.01 s
6-80
LCP Potmeter Enable
1
6-81
LCP potentiometer Low Ref.
0
6-82
LCP potentiometer High Ref.
50
6-90
Terminal 42 Mode
[0] 0-20 mA
6-91
Terminal 42 Analog Output
[0] No operation
6-92
Terminal 42 Digital Output
[0] No operation
6-93
Terminal 42 Output Min Scale
0%
6-94
Terminal 42 Output Max Scale
100%
Table 5.14

5.1.12 7-** Controllers

Parameter
Parameter Description
Default Value
Number
7-20
Process CL Feedback 1 Resource
[0] No function
Process PI Normal/ Inverse
7-30
Control
[0] Normal
7-31
Process PI Anti Windup
[1] Enabled
7-32
Process PI Start Speed
0 Hz
7-33
Process PI Proportional Gain
0.01
7-34
Process PI Integral Time
9999 s
7-38
Process PI Feed Forward Factor
0%
7-39
On Reference Bandwidth
5%
Table 5.15
®
MG02C602 - VLT
is a registered Danfoss trademark
RSPSupply - 1-888-532-2706 - www.RSPSupply.com
http://www.RSPSupply.com/p-12769-Danfoss-132F0026-VFD-Micro-Drive-440V-5HP.aspx
Change During
Conversi
2 Setup
Type
Operation
on Index
All set-ups
TRUE
0
Uint8
All set-ups
TRUE
-
Uint8
All set-ups
TRUE
-2
Uint16
All set-ups
TRUE
-2
Uint16
All set-ups
TRUE
-2
Uint16
All set-ups
TRUE
-2
Uint16
5
All set-ups
TRUE
-3
Int32
All set-ups
TRUE
-3
Int32
All set-ups
TRUE
-2
Uint16
1 set-up
TRUE
-
Uint8
All set-ups
TRUE
-2
Uint16
All set-ups
TRUE
-2
Uint16
All set-ups
TRUE
-3
Int32
All set-ups
TRUE
-3
Int32
All set-ups
TRUE
-2
Uint16
1 set-up
FALSE
-
Uint8
All set-ups
TRUE
-3
Int32
All set-ups
TRUE
-3
Int32
All set-ups
TRUE
-
Uint8
All set-ups
TRUE
-
Uint8
All set-ups
TRUE
-
Uint8
All set-ups
TRUE
-2
Uint16
All set-ups
TRUE
-2
Uint16
Change During
Conversi
2 Setup
Type
Operation
on Index
All set-ups
TRUE
-
Uint8
All set-ups
TRUE
-
Uint8
All set-ups
TRUE
-
Uint8
All set-ups
TRUE
-1
Uint16
All set-ups
TRUE
-2
Uint16
All set-ups
TRUE
-2
Uint32
All set-ups
TRUE
0
Uint16
All set-ups
TRUE
0
Uint8
59
5