1.3. CONTROL TERMINALS

External braking
BU-
unit (optional)
R1K
Strip X1
Function
Programmable/configurable analog differential input. Signal: terminal 1.
1
Analog input 1
Reference point: terminal 2. Default setting: Ramp ref 1
2
Programmable/configurable analog differential input. Signal: terminal 3.
3
Analog input 2
Reference point: terminal 4. Default setting: none
4
Programmable/configurable analog differential input. Signal: terminal 5.
5
Analog input 3
Reference point: terminal 6. Default setting: none. (1)
6
Reference voltage +10V; Reference point: terminal 9
7
+10V
Reference voltage -10V; Reference point: terminal 9
8
-10V
Internal 0V and reference point for±10V
9
0V
12
Enable drive
Inverter enable; 0V or open: inverter disabled; +15...+30V: Inverte enabled
13
Inverter start command; 0V or open: No start; +15...+30V: Start
Start
14
OV or open: Fast stop.
Fast stop
15
External fault OV or open: External fault.
16
Reference point for digital inputs and outputs, term.12...15, 36...39, 41...42
COM D I/O
Reference point for + 24V OUT supply, terminal 19
18
0 V 24
19
+24V supply output. Reference point: terminal 18 or 27 or 28
+24V OUT
Analog output
21
Program.analog output; def.setting: Motor speed. Ref. point: term.22
1
22
0V
Internal 0V and reference point for terminals 21 and 23
Analog output
23
Program.analog output; def.setting: Motor current. Ref. point: term.22
2
BU comm.
26
VeCon controlled BU-... braking units command. Ref. point: term.27.
output
27
0 V 24
Reference point for BU-... command, terminal 26
28
RESERVED
29
RESERVED
Digital input 1
36
Programmable digital input; default setting: none
Digital input 2
37
Progr. digital input; def. setting: none. Configurable as 2nd encoder index qualifier
Digital input 3
38
(setting via S30 jumper,
Programmable digital input; default setting: none. Configurable as 1st encoder
Digital input 4
39
index qualifier ("Digital input 4" parameter must be set 0=OFF ).
Digital output
41
1
Programmable digital output; default setting: none
Digital output
42
2
Supply D O
Supply input for digital outputs on terminals 41/42. Ref. point: term.16.
46
78
Motor PTC
Motor PTC sensing for overtemperature (cutoff R1k if used)
79
Function
Strip X2
80
OK relay
Potential- relay contact OK relay (closed=OK)
contact
82
83
Potential-relay contact configurable (relay 2).
Relay 2
contact
Default: open 0 drive stopped
85
—————— Quick Start up ——————
+15...+30V: No Fast stop.
+15...+30V: No External fault
"Digital input 3" parameter must be set 0=OFF
max
±10V
0.25mA
(20mA when
current ref
input)
+10V/10mA
-10V/10mA
-
+30V
3.2mA @ 15V
5mA @ 24V
6.4mA @ 30V
-
-
+22...28V
120mA @ 24V
±10V/5mA
-
±10V/5mA
+28V/15mA
-
-
+30V
3.2mA @ 15V
5mA @ 24V
)
6.4mA @ 30V
+30V/40mA
+30V/80mA
1.5mA
max curr.
250V AC
1 A AC11
250V AC
1 A AC11
QS