Encoder / Jumpers setting
DE
SE
The jumper S17 selects the inhibition or the enabling of the channel C pulses reading. It has to be correctly
selected in order to detect appropriately the encoder loss alarm.
S17 ON : channel C (index) reading=ON
S17 OFF: channel C (index) reading=OFF
(*) If the encoder is not provided of the zero channel : S17=OFF
Encoder type
DE
SE
DE
SE
Ch.4
58

Table 4.4.2.2: Encoders setting via S11...S23 jumpers

S11
S12
S13
OFF OFF OFF OFF OFF OFF ON (*)
ON
ON
ON
Table 4.4.2.3: Encoders connections
Shielded
1
2
3
cable
B- +8V C+
Internal +5V Encoder Power Supply
l
l
8 pole
l
l
8 pole
Internal +8V Encoder Power Supply
l
l
l
8 pole
l
l
l
8 pole
S14
S15
S16
S17
-
ON
ON
ON
XE CONNECTOR PIN
4
5
6
7
8
C-
A+
A-
0V
B+ +5V E+
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
AVy - HGB
S18
S19
S20
S21
S22
-
-
-
-
-
-
-
-
-
-
9
10
11
12
13
E-
F+
F-
l
l
l
l
S23
-
-
ai3150
14
15
G+
G-
ai3160