SETPOINT CONTROL

Set gradient
The "Set gradient" function sets a gradual variation
of the setpoint, with programmed speed, between two defined
values. If this function is active (
on and at auto/man switching the initial setpoint is assumed
equal to the PV, and the local or selected set is reached with
set gradient. Every variation of set, including variations of the
local setpoint, is subject to the gradient.
The value of remote setpoint SP.rS is not saved in eeprom.
The set gradient is inhibited at switch-on when self-
tuning is enabled.
234
g. s p
22
259
g. s 2
265
xot
Multiset
The MULTISET function determines the local setpoint
by selecting the value from Setpoint 1 (SP.1) or from Setpoint
2 (SP.2) based on the state of a digital input or by setting from
a serial line.
The variation between Setpoint 1 and Setpoint 2
can take place with gradient: parameter G.SP determines the
speed for reaching Setpoint 1 and parameter G.S2 defines
the speed for reaching Setpoint 2.
The MULTISET function is enabled with parameter
hd.1 and automatically enables the gradient function.
Selection between Setpoint 1 and Setpoint 2 can be seen by
means of LED.
191
hd. 1
230
SP. 1
482
231
SP. 2
483
44
other than 0), at switch-
g. s p
R/W
Set gradient
R/W
Set gradient relative to SP2
R/W
Select hot runner functions
Enable multiset:
R/W
control instruments via serial
R/W
Setpoint 1
R/W
Setpoint 2
AL
Absolute alarm
Referred to current
setpoint
Reverse alarm
Direct alarm
Setpoint < AL
0.0 ...999.9 digit / min
( digit / sec see SP.r )
0.0 ...999.9 digit / min
( digit / sec see SP.r )
Table of hot runner functions
Fault action
Enable
power if PV is
hot runners
not stabilized
0
FA.P
1
X
Average power
2
FA.P
3
X
FA.P
4
FA.P
5
X
Average power
6
FA.P
7
X
FA.P
+8 enable GS.2
FA.P – see alarm for probe in short or connection error (SBR-ERR)
(*) if set gradient is set
SP
SP2
SP1
ON
IN1
LOC/REM
Multiset table
Enable
Enable
Multiset
virtual instrument
0
1
X
2
X
3
X
X
+16 For Heat/Cool control Ctr only: CT connected to cool output
Lo.L...HI.L
Lo.L...HI.L
80415F_MSW_GFX4-IR_05-2019_ENG
Setpoint profile
Time
(min. or sec.)
Delay
(parameter HY.n)
Enable
preheating softstart
X
X
X
X
SP1
(*)
SPrem
ON
0.0
0.0
0
t
t
t
0
100
200