10. Error messages and trouble shooting
Message
DC Current High
Ground Current
HW AC OCR
HW Bus OVR
HW COMM1
HW COMM2
HW Connect Fail
92
Possible cause
Switching device in boost is defective. ●
Driver for boost is defective.
Input current detection circuit mal-
function.
PV array insulation fault.
Large PV array capacitance between
Plus to Ground or Minus to Ground.
Either side of boost driver or boost
choke malfunction.
Detection circuit malfunction.
Large grid harmonics.
Switching device is defective.
Detection circuit malfunction.
Driver for boost is defective.
Voc of PV array is > 1000 V
Surge occurs during operation.
Detection circuit malfunction.
DSP is idling.
The communication connection is
disconnected.
The communication circuit malfunc-
tion.
Red. CPU is idling.
The communication connection is
disconnected.
Power line is disconnected inside
solar inverter.
Current feedback circuit is defective.
Solution
Check all switching device in boost.
Check the driver curcuit for boost
inside the solar inverter.
Check input current detection circuit.
Check the insulation of DC inputs.
Check the capacitance (+ <-> GND
& - <->GND), must < 2.5 µF. Install a
external transformer if necessary.
Check boost driver & boost choke.
Check the detection circuit inside
solar inverter.
Check the utility waveform. Grid con-
nection of inverter needs to be far
away from non-linear load if neces-
sary.
Check all switching devices in inverter
stage.
Check the detection circuit inside the
solar inverter.
Check the driver circuit for boost
inside solar inverter.
.
Modify the solar array setting, and
DC
make V
DC
Call Delta Support.
Check the detection circuit inside
solar inverter.
Check reset and crystal in DSP.
Check the connection between DSP
and COMM.
Check the communication circuit.
Check reset and crystal in Red. CPU.
Check the connection between Red.
CPU and DSP.
Check the power lines inside solar
inverter.
Check the current feedback circuit
inside solar inverter.
less than 1000 V
.
DC