Epo (External Power Off) - Delta RPI M50A_120 Installation And Operation Manual

Table of Contents

Advertisement

8.9

EPO (External Power Off)

Overview
With this function you can set the type of contact for the EPO function (normally open or normally closed).
Accessing the menu
Main menu > Install Settings > EPO
1 0 . S e p 2 0 1 4 1 5 : 3 2
S t a t u s :
O n G r i d
P o w e r :
E - T o d a y :
I n v e r t e r I n f o .
G e n e r a l S e t t i n g s
I n s t a l l S e t t i n g s
A c t i v e / R e a c t i v e P w r
F R T
G r i d S e t t i n g s
D C I n j e c t i o n
D r y C o n t a c t
R C M U :
E P O :
N o r m a l C l o s e
Confi gurable Parameters
Parameter
EPO
Installation and Operation Manual for RPI M50A
Installation and Operation Manual for RPI M50A
1.
When the default information is displayed, press any button to open the
main menu. Otherwise, repeatedly press the button
0 W
menu is displayed.
0 k W h
2.
Use the buttons
To confi rm your selection, press the button
3.
The menu is protected by password 5555. Use the buttons
to set each digit.
To confi rm a digit, press the button
4.
Use the buttons
displayed behind the menu entry.
O N
5.
To start editing the parameter value, press the button
6.
To change the parameter value, use the buttons
To confi rm your selection, press the button
To cancel the action, press the button
Description
Sets the type of contact for the relais (normally
closed or normally open).
and
to select Install Settings.
ENT
.
ENT
and
to select EPO. The current setting is
ENT
.
ESC
Value range
Normal Open | Normal Close
Default setting: Normal Close
8 Settings
until the main
ESC
.
and
.
ENT
and
.
67
67