4.8

Information on the type label

Fig. 4.2:
RPI M50A_120 type label
Information on type label
10 s
DC Input
200-1000Vdc
MPPT 520-800Vdc
1000Vdc
50A*2 max.
Isc: 60A*2 max.
AC Output
220/380, 230/400 Vac
3P3W or 3P4W
50/60 Hz
50kW nom.
55kW/55kVA
80A max.
cos φ 0.8 ind ~ 0.8 cap
IP Code: IP65 (Electronics)
Protective Class: I
AC Over voltage category: III
Installation and Operation Manual for RPI M50A
Description
This inverter has no transformer.
Risk of death by electrocution
Potentially fatal voltage is present when the inverter is in operation that remains for
10 seconds after being disconnected from power.
Never open the inverter. The inverter contains no components that must be main-
tained or repaired by the operator or installer. Opening the cover will void the war-
ranty.
Read the manual delivered with the inverter before working with the inverter and
follow the instructions contained in the manual.
The housing of the inverter must be grounded if this is required by local regulations.
DC input voltage range
MPP input voltage range with full power (with symmetrical load)
Maximum DC input voltage
Maximum DC input current per DC input (50 A for each DC input)
DC short circuit current
AC Nominal voltage
The inverter can be connected to 3-wire systems (3 phases + PE) and 4-wire sys-
tems (3 phases + N + PE)
AC Nominal frequency
Nominal active power
Maximum active/reactive power
Maximum AC current
Range of cos φ
Protection degree for the electronics according to EN 60529
Safety class according to EN 61140
AC overvoltage category according to IEC 62109-1
4. Product overview
Fig. 4.3:
RPI M50A_122 type label