P o w e r L i m i t
P o w e r v s . F r e q u e n c y
P ( V )
M o d e :
F S t a r t :
5 0 . 2 0 H z
F R e c o v e r y : 5 0 . 2 0 H z
G r a d i e n t :
M o d e :
F S t a r t :
5 0 . 2 0 H z
F R e c o v e r y : 5 0 . 2 0 H z
G r a d i e n t :
Confi gurable Parameters
Parameter
Mode
F Start
F Recovery
Gradient
T Recovery
Do not change this setting without prior
consultation with Delta Solar Support.
Installation and Operation Manual for RPI M50A
Installation and Operation Manual for RPI M50A
5.
Use the buttons
rent setting is displayed behind the menu entry.
O N
6.
To change the mode, use the buttons
ton
.
ENT
1 0 0 %
To switch the function on, select ON and press the button
To switch the function off, select OFF and press the button
you switch the function off, you can ignore the following steps.
7.
O N
Use the buttons
ton
.
ENT
1 0 0 %
8.
To change the parameter value, use the buttons
To confi rm your setting, press the button
To cancel the action, press the button
9.
Repeat steps
Description
Switches the function on and off.
The grid frequency at which the inverter starts to limit the active power according to
the Gradient parameter.
The grid frequency at which the inverter reconnects to the grid or at which the
inverter feeds-in full power again. The behavior depends on the selected country and
grid.
Adjustment of the active power fed into the grid in percent per Hz when the grid fre-
quency is between F Start and F Stop.
When the grid frequency drops to F Recovery, the inverter will wait for the time
defi ned in T Recovery before it returns to normal operating behavior.
and
to select Power vs Frequency. The cur-
and
to select a parameter and press the but-
7
to
8
for all parameters you want to change.
8 Settings
and
and press the but-
.
ENT
ENT
and
.
ENT
.
ESC
. When
73
73