PROFIBUS/MPI interface X9
Pinno.
1
2
3
4
5
6
7
8
9
Shield
1
PROFINET LAN X3 Port P0, P1, P3
Pinno.
1
2
3
4, 5
6
7, 8
S
1
2
SIMATIC IPC647D
Operating Instructions, 01/2014, A5E32996306-AA
1
Short name
LTG_B
RTS_AS
M5EXT
P5 EXT
LTG_A
RTS_PG
Optional product variant
Short name
RD+
RD-
TD+
SYMR
1
TD-
SYMT-
1
LED 1
LED 2
Optional product variant
Auto Negotiation and auto crossover are supported
Meaning
Not used
Not used
Signal line B of MPI module
RTSAS, control signal for received data
stream. The signal is "1" when the directly
connected AS is sending.
M5EXT return line (GND) of 5 V power supply.
The current load of an external consumer
connected between P5EXT and M5EXT may
not exceed the 90 mA.
P5EXT power supply (+5 V) of the 5 V power
supply. The current load of an external
consumer connected between P5EXT and
M5EXT may not exceed the 90 mA.
Not used
Signal line A of the MPI module
RTS output signal of the MPI module. The
control signal is "1" when the programming
device is sending.
on connector casing
Meaning
Receive data
2
Receive data
2
Send data
2
Internal 75 Ohm terminating resistor
Receive data
2
Internal 75 Ohm terminating resistor
Shield
Lit green: link
Lights up yellow: activity
Technical specifications
8.5 Hardware description
Input / output
Input/output
Input
Output
Output
Input/output
Output
Input / output
Input
Input
Output
_
Output
_
141