Table 1-18. Blade Messages (continued)
Message
Unsupported CPU
stepping detected.
Warning! A fatal
error has caused
system reset.
Please check the
event log for
details.
Warning! Following
faulty DIMMs are
disabled: DIMM xx ,
DIMM yy .
Warning! No
microcode update
loaded for
processor n .
Warning: The
current memory
configuration is
not validated.
Change it to the
recommended memory
configuration or
press any key to
continue.
76
About Your System
Causes
Processor is not supported
by the blade.
Unspecified error.
Faulty or improperly
seated memory modules.
Unsupported processor.
There is no memory
configuration error, but
the memory configuration
is not recommended by
Dell.
Corrective Actions
Check for a BIOS update
using the Dell Support
website at support.dell.com.
If the problem persists,
install a supported processor.
See "Processors" on
page 128.
Check the system event log
for information about the
error.
See "Troubleshooting Blade
Memory" on page 191.
Update the BIOS firmware
using the Dell Support
website at support.dell.com.
See "System Memory" on
page 105.