Dell PowerEdge M605 Hardware Owner's Manual page 73

Hide thumbs Also See for PowerEdge M605:
Table of Contents

Advertisement

Table 1-18. Blade Messages (continued)
Message
No boot device
available.
No boot sector on
hard-disk drive.
No timer tick
interrupt.
Not a boot
diskette.
PCI BIOS failed to
install.
Plug & Play
Configuration
Error.
Causes
Faulty or missing diskette
drive, optical drive, or hard
drive.
An operating system is not
on the hard drive.
Faulty blade board.
Not a bootable diskette.
Faulty or improperly
installed mezzanine card.
Error encountered in
initializing PCI device;
faulty blade board.
Corrective Actions
Check the Integrated
Devices configuration
settings in the System Setup
program and ensure that the
controller for the boot
device is enabled. See "Using
the System Setup Program"
on page 79. Ensure that the
controller for the boot
device is enabled.
If the problem persists,
replace the drive. See "Hard
Drives" on page 142.
Check the hard-drive
configuration settings in the
System Setup program. See
"Using the System Setup
Program" on page 79.
See "Getting Help" on
page 217.
Use a bootable diskette.
Reseat the mezzanine card.
See "I/O Module Mezzanine
Cards" on page 123. If the
problem persists, see
"Getting Help" on page 217.
Set the NVRAM_CLR
jumper to "on" and reboot
Figure 7-1,
the blade. See
Figure 7-2,
Figure 7-3 or
Figure 7-4 for the jumper
location.
Check for a BIOS update. If
the problem persists, see
"Getting Help" on page 217.
About Your System
73

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge m600Poweredge m805Poweredge m905

Table of Contents