Table 1-18. Blade Messages (continued)
Message
Error: Memory
failure detected.
Memory size
reduced. Replace
the faulty DIMM as
soon as possible.
Error programming
flexAddress (MAC)
for bus , device ,
function .
Error programming
flexAddress (iSCSI
MAC) for bus ,
device , function .
Error resetting
NIC after
programming
flexAddress for
bus , device ,
function .
FBD training
error: The
following branch
has been disabled:
Branch x .
Gate A20 failure.
General failure.
70
About Your System
Causes
Faulty or improperly
seated memory modules.
FlexAddress (virtual
MAC) is not supported on
the specified device.
FlexAddress (virtual
MAC) is not supported on
the specified device.
FlexAddress (virtual
MAC) is not supported on
the specified device.
The specified branch
(channel pair) contains
DIMMs that are
incompatible with each
other.
Faulty keyboard controller
(faulty blade board).
Operating system
corrupted or improperly
installed.
Corrective Actions
See "Troubleshooting Blade
Memory" on page 191.
Information only
Information only
Information only
Ensure that only Dell
qualified memory is used.
Dell recommends
purchasing memory upgrade
kits directly from
http://www.dell.com or your
Dell sales agent to ensure
compatibility.
See "Getting Help" on
page 217.
Reinstall the operating