12 (Optional) Press <F2> to enter the System Setup program, and check the
System Memory setting on the main System Setup screen.
The system should have already changed the value to reflect the newly
installed memory.
13 If the value is incorrect, one or more of the memory modules may not be
installed properly. Repeat step 1 through step 12 of this procedure,
checking to ensure that the memory modules are firmly seated in their
sockets.
14 Run the system memory test in the system diagnostics. See "Running
System Diagnostics" on page 197.

Removing Memory Modules

CAUTION:
cover and access any of the components inside the system. Before you begin this
procedure, review the safety instructions that came with the system.
CAUTION:
powered down. Allow time for the DIMMs to cool before handling them. Handle
the DIMMs by the card edges and avoid touching the DIMM components.
1 Remove the blade. See "Removing a Blade" on page 96.
2 Open the blade. See "Opening the Blade" on page 100.
3 Locate the memory module sockets. See Figure 7-3 or Figure 7-4.
4 PowerEdge 905 systems only - You must slide the system board back in the
blade chassis to access memory sockets C1 through C4 and D1 through
D4. See step 1 through step 7 in "Removing the System Board" on
page 150.
5 Press down and out on the ejectors on each end of the socket until the
memory module pops out of the socket. See Figure 3-11.
6 PowerEdge 905 systems only - If you removed the system board to access
the memory modules, reinstall the system board.
7 Close the blade. See "Closing the Blade" on page 104.
8 Install the blade. See "Installing a Blade" on page 98.
122
Installing Blade Components
Only trained service technicians are authorized to remove the system
The DIMMs are hot to the touch for some time after the blade has been