To connect the Avocent iKVM switch to a supported analog switch:
1 If the switch does not require a SIP to connect to the iKVM (see Table 1-8),
connect a Cat5 (or newer) cable to the RJ-45 ACI port on the iKVM
module. See Figure 1-13.
Connect the other end of this cable to the ARI port on the external switch.
If the analog switch requires a USB SIP (see Table 1-8), connect a USB SIP
to the iKVM, then connect a Cat5 (or newer) cable to the SIP. Connect the
other end of this cable to the ARI port on the external switch.
2 Connect both the analog switch and the system to an appropriate power
source.
3 Power up the system.
4 Power up the
NOTE:
If the external analog switch is powered up before the system, it may result
in only one blade displaying in the analog switch OSCAR, instead of 16. If this
behavior occurs, shut down and restart the switch so the entire complement of
blades is recognized.
NOTE:
In addition, to the steps outlined above, some external analog switches may
require you to perform additional steps to ensure that the iKVM switch blades
appear in the external analog switch OSCAR. See the external analog switch
documentation for additional information.

Tiering the Avocent iKVM Switch From a Digital KVM Switch

The iKVM switch may also be tiered from a digital KVM switch such as the
Dell 2161DS or 4161DS, or a supported Avocent digital KVM switch. Many
switches may be tiered without the need for a SIP (see Table 1-9).
Table 1-9. Cabling Requirements for External Digital KVM Switches
Switch
Dell PowerConnect 2161DS,
4161DS
Avocent DSR 800, x16x, x010, x031,
x030, x035,102x (except 1024)
Avocent DSR 1024
analog switch.
external
Tiering Requirements
Seamless tiering using ACI port
and Cat 5 cable
Dell USB SIP required with Cat 5