Dell PowerEdge M605 Hardware Owner's Manual page 72

Hide thumbs Also See for PowerEdge M605:
Table of Contents

Advertisement

Table 1-18. Blade Messages (continued)
Message
Memory address
line failure at
address , read
value expecting
value .
Memory double word
logic failure at
address , read
value expecting
value .
Memory odd/even
logic failure at
start address to
end address .
Memory write/read
failure at
address , read
value expecting
value .
Memory mirroring
enabled.
Memory tests
terminated by
keystroke.
72
About Your System
Causes
Faulty or improperly
installed memory modules,
or faulty blade board.
Memory mirroring
enabled
The spacebar or ESC key
was pressed during POST
to terminate the memory
test.
Corrective Actions
Ensure that all memory
modules are properly
installed. See
"Troubleshooting Blade
Memory" on page 191. If the
problem persists, see
"Getting Help" on page 217.
Information only.
Information only.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge m600Poweredge m805Poweredge m905

Table of Contents