Table 1-18. Blade Messages (continued)
Message
Read fault.
Remote
Configuration
update attempt
failed.
Sector not found.
Seek error.
Seek operation
failed.
Shutdown failure.
Spare bank
enabled.
The amount of
system memory has
changed.
74
About Your System
Causes
Faulty diskette, diskette
drive, or optical drive.
Blade could not
implement Remote
Configuration request.
Faulty diskette or hard
drive.
Shutdown test failure.
Memory sparing enabled.
Faulty memory module.
Information only, if you
have changed the memory
configuration.
Corrective Actions
Replace the diskette. Ensure
that the drive cable is
properly connected. See
"Troubleshooting USB
Devices" on page 183 or
"Troubleshooting Hard
Drives" on page 192 for the
appropriate drive(s)
installed in your system.
Retry Remote
Configuration.
Replace the diskette. If the
problem persists, see
"Troubleshooting Hard
Drives" on page 192 for the
appropriate drive installed in
your system.
Ensure that all memory
modules are properly
installed. See
"Troubleshooting Blade
Memory" on page 191. If the
problem persists, see
"Getting Help" on page 217.
Information only.
See "Troubleshooting Blade
Memory" on page 191. If the
problem persists, see
"Getting Help" on page 217.