Figure 3-31. Removing and Installing the Storage Controller Card (Half-Height Blade
Shown)
1
storage controller card

Installing the Storage Controller Board

1 To place the storage controller board onto the system board, align the
controller board so that the tabs on the metal system board tray fit through
the corresponding notches in the edges of the controller board.
2 Slide the board towards the connector on the system board until the
boards's edge connector is fully seated.
3 Reinstall the system board. See "Installing the System Board" on page 153.
4 Close the blade. See "Closing the Blade" on page 104.
5 Install the blade in the system. See "Installing a Blade" on page 98.
1
2
release lever
Installing Blade Components