Installing An Expansion Card - Huawei USG6000 Series Hardware Manual

Version v100r001 & v500r001
Hide thumbs Also See for USG6000 Series:
Table of Contents

Advertisement

HUAWEI USG6000 Series
Hardware Guide
l
l
Procedure
Step 1 Loosen and remove the screw of the ground terminal on the lower left of the USG front panel.
Step 2 Align the M4 end of the PGND cable with the opening of the ground terminal and tighten the
screw.
Step 3 Connect the M6 end of the PGND cable to the ground terminal of the cabinet or workbench.
Figure 3-64 Connecting a PGND cable
Secospace USG6000
1
3
5
7
----End
Follow-up Procedure
Verify the following after the cabling is complete:
l
l

3.5.3 Installing an Expansion Card

This section describes how to install an expansion card and avoid any damage.
Issue 08 (2017-06-30)
Phillips screwdriver
Multimeter
2XG8GE
0
1
2
3
4
5
6
7
2
4
6
2XG8GE
0
1
2
3
4
5
6
7
8
PGND cable
1
The PGND cable is securely connected to the ground terminal.
The electrical resistance between the ground terminal and ground point is less than 5
ohm on a multimeter.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4
0
1
0
1
2
3
1
1
3
5
0
0
2
4
8GEF
10G
0
1
1
0
10G
Cabinet ground point
2
3 Hardware Installation
5
6
7
7
6
3
315

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents