Pos: 427 /Te chnis che Dok umenta tion/A lle G eräte/ Überschr ifte n/Üb erschrif te n 1.1/S/ Überschr ift 1.1: S ingle Motor Module / Doub le M otor M odule / P ower M odule @ 17\mod_ 1253261415575_ 75.docx @ 444618 @ 2 @ 1
16.3
Single Motor Module / Double Motor Module
Pos: 428 /Te chnis che Dok umenta tion/ Leis tungsmesstechnik/POWE RDYNO/053101
M SR/ BA/Inhalt: 0531 SINAMICS Smart Line Module 16 k W und 36 k W / S ingle M otor Mod ule @ 17\mod_ 1253259413890_75.d ocx @ 444591 @ @ 1
Status
Ready
DC link (H201)
(H200)
Off
Off
Off
Orange
Green
Red
Orange
Orange
Red
-
Green / Red
-
Green /
Orange
-
or
Red / Orange
Hazard DC link voltages may be present at any time regardless of the status of the "DC link" LED.
The warning information on the components must be carefully observed!
Pos: 429 /-----Format- ----/MANUE LLE R UMBRUCH Se ite numbruch @ 0\mod_ 1134403577687_0.docx @ 1277 @ @ 1
Description, Cause
Electronics power supply is missing or outside per-
missible tolerance range.
The component is ready for operation and cyclic
DRIVE-CLliQ communication is taking place.
The component is ready for operation and cyclic
DRIVE-CLiQ communication is taking place.
The DC link voltage is present.
The component is ready for operation and cyclic
DRIVE-CLiQ communication is taking place.
The DC link voltage is too high.
DRIVE-CLiQ communication is being established.
At least one fault is present in this component.
Note:
LED is driven irrespective of the corresponding mes-
sages being reconfigured.
Firmware is being downloaded.
Component recognition via LED is activated
(Ip0124).
Note:
Both options depend on the LED status when com-
ponent recognition is activated via p0124 = 1.
123
Remedy
-
-
-
Check supply voltage
-
Remedy and
acknowledge fault
-
-
BA053101-en
Need help?
Do you have a question about the POWERDYNO MSR Series and is the answer not in the manual?