Servopack - YASKAWA CPCR-MR08C Bulletin

Servopack dc servomotor controller for speed control
Table of Contents

Advertisement

INDICATOR_ r__lL_]ll I _
3.4
PRECAUTIONS
FOR APPLICATION
WINDOW
%-II
IL>
3.4.1
Coating
(Varnish)
Treatment
When used
in ambients
where
oil mist is likely
to
Note:
If the fuse is blown,
deposit
or humidity
is high,
Servopack
internal
the indicatorwindowon the
insulating
resistance
drops
due to oil mist or moisture
fuse casing
shows whiteto
and
malfunction
may occur.
For use in a severe
indicatea blownfuse.
ambient condition, the type of treatment for severe
(a)
Types CPCR-MR01C
to -MR07C
environment
should
be applied.
For the severe
ambient
condition,
types
having
ELEMENT
FUSEHOLDER
control board coated with varnish are available.
eLOWN
FUSE
D=CAT=ON"
3. 4. 2 Minus
Load
b
by
load;it isimpossible,
The
motor
is rotated
the
by
the
use
of CPCR-MR[]C,
to apply
brake
"Whenfuseis blown, t he element
(regenerative
brake)
against
this
rotation
and
indicator c omes out.
achieve
continuous
running,
(b)
Types CPCR-MR08C
to-MR99C
Example:
Driving
a motor
to lower
objects
(with
Fig. 3.17
Blown Indication of Built-in Fuse
no counterweight)
Since Servopack
types
CPCR-MR08C
to -MR99C
3.3.7
Current
Monitor
has the regenerative brake capability of short
time (corresponding
to the motor
stopping
time),
Motor
current
appears
as a voltage
signal at terminal
for application
to a minus
load, contact
the company.
(_ of Servopack
types
CPCR-MR08C
to -MR99C
or
For regenerative
unit type JUSP-PG
used
with
protection
device
type
JESP-PT
(Table
3.4).. The
types
CPCR-MR01C
to-MR07C,
refer to Par. 3.8.2.
signal is used
to detect overload
of the motor.
The
connecting
load must
have
input
impedance
of
10 kt2
or greater
(Normally
open).
3.4.3
Type CPCR-MR[-_]CW
Application
Types
CPCR-MR08CW
to -MR55CW
are applicable
Table
3.4
Voltage
Level
of Current
to harmful
ambients
containing
iron powder
and
Monitor Terminals
cutting oil, such as in cutting and millingmachines
or car factories.
The
characteristics
are the same
SERVOPACK Type
Current Monitor Terminal Voltage
(Protection Device T ype)
(With Terminal Q opened)
as those
of types
CPCR-MR08C
to -MR55C,
but
the construction
differs in that cooling
air is taken
CPCR-MR01Ct0-MR07C
from the outside of the unit and discharged
to
+ (JESP-PT)
0.045 V -t- 10 % A
the outside
[Fig.
3.18
(a)
and
(b)].
CPCR-MR08C
0.06V
-t- 10%
A
CPCR-MR15C
0.05V
+_ 10%
A
PANEL
PANEL
/
CPCR-MR22C
0.03V
-t- 10%
A
_
CPCR-MR55C
0.02V
-t- 10%
A
t
I
I%
COOLING_
AIR
CPCR-MR75C
0.015V
-t- 10%
A
CPCR-MR99C
0.01V
± 10%
A
qp
COOLING
AIR
3. 3. 80verspeed
Drive (O.S
Drive)
(a)
Cooling System for
(b)
Cooling System for
Type CPCR-M R[_]C
Type CPCR-M R[_]CW
To
fully develop
the characteristic
of Minertia
Motor J series (large torque
at low speed),
CPCR
-MR _-j CJ and
CPCR-MR
[-] C-J
provides
the
O.S
Fig
3 18
Cooling
System
drive
function
enabling
an overspeed
drive
up
to approxin_ately
1.5
to 2 times
the
rated
speed
within
the
allowable
speed
range
of the
motor.
It
is
therefore
unnecessary
to control
the
current
limit
characteristic
determined
by
the
motor
(according
to the
speed,
automatic
current
limit
is applied
from the
outside).
31