External Terminals - YASKAWA CPCR-MR08C Bulletin

Servopack dc servomotor controller for speed control
Table of Contents

Advertisement

2.3.2
External
Terminals
for
Types
CPCR-MR08C
to -MR99C
Table
2.3
External
Terminals
for
Types
CPCR-MR08C
to -MR99C
Terminal Symbol
Name
Description
® O O
Main Circuit
Power Input
Three phase 200/220
VAC _+10 %, 50/60
Hz
(_) Q
Control
Circuit
Power Input
Single phase 200/220
VAC _+10 %, 50/60
Hz
©
(_
DC Reactor
and Thermal
Connects
DC reactor
to thermal
overload
((i_)
([_)'_) Overload
Relay
Connection
Relay
in series
Main Circuit
Connects
terminal
_) to motor terminal (_), and terminal
@) to motor
® (_)
Motor
Connection
terminal
®.
Regenerative
Resistance
Used
as the
internal
junction
terminal
of the
regenerative
resistor
(L_
(_)
Junction
Terminal
unit.
Cannot
be connected
from the outside t.
Thermo
Switch
Junction
Used
for only
CPCR-MR55C(W)
to -MR99C
shortcircuiting
across
( (_
(_)
Terminal
(_)-(_)
externally.
Cannot
be connected
from the outside.
(_ (_)
Speed
Reference
Input
(_ is at SG 0V.
The
rated forward
rotation
is given
at _+6 V.
_) _)
TG Input
(_) is at SG 0V.
Connect TG(--) to (_) and TG(+) to (_.
Used
to provide
the rated
speed
at voltages
(+ 2 to _+ 10V) other
than
the
(_) (_)
Auxiliary
Input
rated reference
voltage,
+6V.
Overtravel
Base
off at
Forward-side
base
off when
shortcircuiting
across
(_ and _).
_) (_)
the Forward
Running
Used with
a limit switch.
Overtravel
Base
off at
Reverse-side
base
off when
shortcircuiting
across
(_) and (_).
_) (Z)
the Reverse
Running
Used with a limit switch.
(U) is at 0 V.
Proportional
drive
when
shortcircuiting
across
(_ and
(_) (_)
Proportional
Drive
@.
At this time, set the speed
reference
to 0 V.
@is
at 0V,@at
+10V,
and@at
--12V.
30mA
can be supplied.
@ @ @
-+12V
Power
Output
Used for speed
setting,
etc.
Control
Circuit
External
Current
Limiting
at
_) @
the Reverse
Running
Used to limit
the current
from
external
at reverse
running.
External Current
Limiting
at
(_) (_
the Forward
Running
Used to limit the current
from
external
at forward
running.
_) @
Current
Monitor
@ is at 0 V.
Armature
current
is observed
at @.
Terminal
to output
servo
trouble.
@ @ @
Servo Trouble
Output
1 NONC contact
((_:
NC,
@:
common,
(_:
NO)
Current
capacity:
100/200
VAC 1 A, 24 VDC 1 A
(_ @
External
Base off
@ is at 0 V.
Shortcircuiting
across
(_) and (_) breaks
bases
at the
forward
and
reverse
running.
(_ @
Optional
Not used.
This
is a free terminal
to be used
for shielded
wires
for TG and
input
or
(_
_
Grounding
grounding.
"_Onlyfor CPCR-MR75C and-MR99C.
Note: Do not use empty terminals to connect the external cir-
tOnly for CPCR-MR99C, separate regenerative resistor unit
cult (some unused terminals may be used in product modifica-
JUSP-RA03 is connected (Fig. 3.23).
tion, so reserve them for possible Servopock r eplacement).
20