1. RATINGS
AND SPECIFICATIONS
1.1
SERVOPACK
RATINGS
AND SPECIFICATIONS
Table 1.1
SERVOPACK Ratings and Specifications
SERVOPACK
Types CPCR-
MR01 C
MR01 CJ
MR02C
MR02CJ
MR05C
MR07C
Motor
Output
kW
0.1
max
0.1
0.2
0.2
0.5
0.77
Control
Method
Single-phase
bridge
rectifying
(power
transformer
installed
separately),
transistorized
PWM
control
Main
Voltage
Single-phase,
200/220VAC
+10%
or
100/110VAC
_10%,
50/60Hz
---1_5%
Power
Circuit
Capacity*
kVA
0.3
0.3
0.5
0.5
1
1.5
Supply
Control
Circuit
Single-phase,
100/110VAC
_+-_ 1 0%,
50/60Hz,
50VA
(with
power
transformer
installed
separately)
Max Output
VoItage
(V MAx)
VDC
-----30 (at +-6A)
--1,100 (at +-3A)
___45 (at +-7A)
--1,100 (at _--+6A)
+85
(at _8A)
--1.80 (at +-13A)
Instantaneous
Max
Output
_--t-15_+
10%
_+ 11 -+ 10%
_+20_+
10%
___15--1.
10%
--1, 20 -t- 10%
__.30--1,
10%
Current
(I MAX)
A
Continuous
Output
Current
(I out) A
--1.6
_--t- 3
--1,7
+ 6
_+ 8
--1,1 3
Current
Limiting
Range
A
+-3 to +-15
+1
to_+11
+-3 to +-20
+3
to +-15
+-3 to _20
+-6 to ±30
Waveform Factor
1.05 and below
Derating Factor
0.95 and below
Speed Control Range
1000 : 1
Load
Regulation
0 to 100%
0.1%
and
below
at rated
speed,
-t-0.05%
and
below
at 1/1000
rated
speed
Voltage
Regulation
--+10%
--1,0.1%
and
below
at rated
speed,
--1,0.02%
and
below
at 1/1000
rated
speed
Temperature
Regulation
--1,0.5%
and
below
at rated
speed,
--1,0.1%
and
below
at 1/1000
rated
speed
25-+35°0
con-
Tach-gen
(TG) Temperature
_0.05%/oC
Regulation
Rated
Reference
Voltage
+-6VDC
(forward
running
at plus
reference)
-o _ -
Resistance
20k_2 + 10%
u_ rr __ Circuit
Time
Constant
35/_s
___20%
Rated Reference Voltage
--1. 2 to -+ 10 V
"5
Resistance
3.3 k_l/V
Circuit
Time
Constant
45/_s
and
below
Speed
Feedback
DC tachometer
generator
feedback
control
(7V/1000r/min)
Built-in
Reference
Power
Supply
--1. 12VDC,
-+30mA
Ambient
Temperature
-- 10"C
to +60°C
(-- 10°C
to +40°C
in panel)
Storage Temperature
--20°C
to -t-60=C
Humidity
85% and below (non-condensing)
Print motor
standard
series,
Minertia
motor:
3 times
motor
inertia
Allowable
Load
Inertia
Cup motor,
Hi-cup
motor,
Minertia
motor
J series:
2 times
motor
inertia
* Forratedoutput
Notes:
fused
for application at a rated reference
voltage other than -t-6 V.
1. Make sure that the power voltage is limited to less than 220 V +10 %
(242 V).
For voltages
higher
than
220 to 242 V, use a step down
trans-
Type Designation
former
to reduce the voltage.
C P C R - M R i_-][_-]C[_-] - [_-]
2. The drive characteristic
of type CPCR-MR[]]C
differs for
Servopoc_$
and
"--_
T
applicable
motors
as shown in Fig. 1.1 (a)and
(b).
The allowable
/
L
current-conduction
time for the instantaneous
rating depends on com-
_!ar_e_s_A_d
Servomotor
to be Applied
binations with the applicable motor and is guaranteed only for time of
• Blank:
Standard
Motor
(Cup
Motor)
start
and
stop
(approx.
ls
or
_ess)
in
the
allowable
inertia
:oi_rlo_i_
I/PWM
See Table 1.2.
range.
An overload
protection
such as motor
locking is
therefore
rsing
" J:
Minertia
Motor J Series (JM)
necessary depending on the application conditions.
• M:
Minertia
Motor Standard
Series(MM)
3. When a servomotor
is driven
by thyristor
drive units, the armature
• H:
Hi-Cup
Motor
(HM)
current
generally
pulsates,
differing
from
that of battery-driven
units.
• 08:
0.75kW
•C:
Cup Motor(CM)
This reduces the average value (component
to "produce torque) of ar-
• 15:
1.5 kW
• P:
Print Motor (PM)
mature current
when the motor rated current
equals armature current
• 22:
2.2 kW
(r/min), and therefore,
it is necessary to reduce the rated torque for the
• 55: 5.5kW
Optional
motor.
• 75:
7.5kW
• 99:
9.9 kW
• Blank:
Standard type
The reduction
rate is termed
the derating
factor.
The derating
• W_:
Externally ventilating fan type
factor of Servopacktype CPCR-MR[]]C is very excellent, 95 % or greater.
Design Revision Order
• L:
Built-in overload detection type
Example:
When type CPCR-MR[]C
or 95 % derating factor is com-
- J:
Overspeed drive type for JM
bined with a motor of rated output 1.5kW(8.183N.m),
the effective
• C:
Second Revision
• Y[]]:
Special order
output(torque) is 1.5kW(8.183N.m)
X0.95(14.25kW).
tType CPCR-MR[]]C
and Type CPCR-MR[]]CW
differ in the shapes and
4. In the speed control range, the lowest speed is defined under the con-
cooling
systems.
For ventilating
construction
with overload
detection
dition not stopped by 100 % load variation.
circuit, the type CPCR-MR[]]CWL
is applied.
5. Speed regulation
is generally
defined as follows:
No load speed--
Full load speed
Speed regulation
=
× 100 96
4
Rated speed