YASKAWA CPCR-MR08C Bulletin page 41

Servopack dc servomotor controller for speed control
Table of Contents

Advertisement

Table 3.7
DB Resistor for DC Servomotor
3.7.4
Tachometer
Connection
DC Servomotor
DB Resistor Type
DB Contactor
When
a tachometer
is connected
to the
tachometer
Type
(RDB)
Type (MC2)
generator,
make
the
connection
as shown
in Fig.
o
UGPMEN-08
3.28,
using
a DC ammeter
of +lmA
(both
swing).
_
PMES-09
QHZ10W 1`0x2P
Using
resistances
1R and 2R and a potentiometer
RA-6E2
I VR,
set the maximum
speed
per full scale.
_
PMES-12
QHZ-Y30Wl£
(B x 3P)
E _
PMES-16
QHY60W 2`0
0. _
PMES-20
QHY60W 5`0
J,
UGJMED-10M
4_
1R
UGJMED-40M
QHY30W 2`0.0,
1
DC TACHOMETER
i SERVOPACK
.5
UGJMED-40L
GENERATOR
_
TYPE CPCR-MR[_.C
UGJMED-60M
QHY30W2_+QHZ10W1_
RA-6E2
L_
._-
._ UGJMED-60L
(Bx 3P)
c co UGJMED-80M
QHY60W
2_
_
UGJMED-80L
UGJMED- 80 K
SGCE0-4 iBx4P)
Notes:
UGCMED
-04
QHY60W
2,0
1. Instrument:
_+1 mA (both swing) ammeter.
UGCMED-
08
2. 1R, 2R and lVR should be selected according to the setting
RA-6E2
of maximum speedperfull scale.
"6
UGCMED
- 15
(B x 3 P)
(select 1R = 2R; 1VR is for fine adjustment)
UGCMED -22
QHY60W 2`0
3. Use ammeter of type DCF-6 or DCF-12N by Toyo Instrument
UGCMED "37
or equivalent.
(D
UGCMED -55
SRCE0-4
UGCMFD-75
(B x 4P)
Fig. 3.28
Tachometer Connection
UGHMED-06
QHY30W 2D,
:_
UGHMED-12
RA-6E2
3.7.5
Transformer
for Multiple
SERVOPACKs
o.
UGHMED-20
(Bx 3P)
UGHMED-30
QHY60W
2 `0
.
Power transformer isneeded when Servopack types
f
UGHMED-44
SRCE0-4(BX4P)
CPCR-MR01C
to -MR07C
are
used.
The
capacity
UGMMEM-06
of one p0wer.transformer is usually limitedto one
-_
UGMMEM-13
Servopack.
Where multiple Servopacks are applied
_
UGMMEM-25
QHY60W2`0
RA-6E2
to one transformer,
a special transformer
is
-o
(B x 3P)
required In this case,contact your Yaskawa
_
UGMMEM-50
.c_
UGMMEM-1A
representative.
_
UGMMKR-2A
QHY60W 2`0 x 2P
SRCE0-4 (Bx4P)
3.8
OPTIONAL
COMPONENTS
3.7..3
Use of Servomotor
with Holding
Magnetic
Brake
3.8.1
Protection
Device Type JESP-PT[_]
When
servomotor
with holding
magnetic
brake
is
Protection
device
type
JESP-PT[-]
for Servopack
used,
use the following timing for signals ON
and
types
CPCR-MR01C
to -MR07C
is available as an
OFF.
The
holding
magnetic
brake
is released
by
option.
Protection
device type JESP-PT[_]
contains
current conduction,
protective circuits to detect overcurrent
and
ON
overvoltage protection.
If any trouble occurs,
HOLDING MAGNETIC
OFF
J BRAKE RELEASED
! OFF
the
protective
circuit
is actuated
and
the indicator
BRAKE
--*,
0.1 s OR MORE*
LED lights
to indicate
the
status.
Operating
status
=t SPEED REFERENCEIt
t'
'i INPUT
l'
cannot be output outside of Servopack.
SPEED REFERENCE 0V
I
!
I
I
By using Servopack
with protective device
,'
OFF
,l
F11 O N
type JESP-PT[-q_., trouble status can be indicated
EXTERNAL BASE
OFF
ON
''
I
'
and output by built-in relays.
The protection
',
devices can be easily connected
to Servopack
using
\,
RUNNING
connectors.
MOTOR ROTATION
STOP
.
i STOP
i-}-1
Prot&ction
device
type
JESP-PT[_-_
contains
functions
such
as TG
trouble
detection
and input/
*Input
speed reference 0.1 second or more after the brake re-
output
prohibition
indication,
and
current
monitor
lease reference
has been input,
terminal.
Type
JESP-PT[:]L
containing
overload
tApply
brake
after the motor
has stopped
completely.
(Do not
use the brake to decelerate
the motor.)
detection
is available
upon
request.
Note:
Arrow_shows
a delay
time
greater
than
the operating
time (10 ms) of one relay.
Fig. 3. 27
Holding Magnetic Brake ON-OFF Timing
39