Exceeding up to max. 160 °C (320 °F)
Step
Exceeding over 160 °C (320 °F)
Step
05–50–00
Page 24
September 01/2018
BRP-Rotax
MAINTENANCE MANUAL LINE
Table 3: Excess temperature up to max. 160 °C (320 °F) max. 15 min.
Procedure
1
The whole oil system must be inspected, repaired or overhauled in accord-
ance with the BRP-Rotax instructions for continued airworthiness.
2
Inspect oil level in the oil tank.
3
Inspect oil cooler for contamination and check the entire oil circuit for cor-
rect functioning.
4
Check that oil lines are routed correctly and undamaged.
5
Cut oil filter housing and inspect filter mat for foreign matter.
6
Carry out oil change.
7
Inspect all further systems for correct functioning.
Table 4: Excess temperature over 160 °C (320 °F) for longer than 15 min.
Procedure
1
The whole oil system must be inspected, repaired or overhauled in accord-
ance with the BRP-Rotax instructions for continued airworthiness.
2
Inspect all further systems for correct functioning.
3
Carry out detailed inspection of the affected engine components.
4
The whole oil system (oil cooler, oil lines) must be inspected.
5
Cut oil filter housing and inspect filter mat for foreign matter.
6
Carry out oil change.
Effectivity: 912 i Series