Rotax 912 i Series Maintenance Manual page 65

Line maintenance
Hide thumbs Also See for 912 i Series:
Table of Contents

Advertisement

Points of Inspection
* no periodic maintenance require-
ment after the first 25 hours of
operation
on radiator cap and/or if the coolant
manufacturer requires a change
interval.
Engine cleaning.
Verify liquid level, replenish as
necessary.
Observe the safety instructions!
Start the engine and run to operating
temperature.
Limits see Operators Manual 912 iS.
Ignition check at _____ rpm engine
speed. Speed drop without LANE:
A (Off)___________rpm
B (Off)___________rpm
A/B (difference)________rpm
Checking the idle speed.
After engine test run, re-tighten the oil
filter by hand (only at cold engine).
Checks for leaks.
Returning engine to service
On the engine identified as per point 5, on the ___________________________the________hr.
Check at______hr. (TSN___, TSO___) was carried out according to recommendations of the engine manu-
facturer and was recorded in the Engine Log book.
Location, Date_______________________
Inspector___________________________
Aircraft mechanic_____________________
Certificate No.______________________
Effectivity: 912 i Series
Edition 2/Rev. 0
BRP-Rotax
MAINTENANCE MANUAL LINE
Interval Operating hours
25*
50
100
18) Engine cleaning
X
X
19) Liquid level check
X
X
20) Engine test run
X
X
Reference
200
600
1000
Flushing the
X
X
X
12–20–20
X
X
X
12–10–00
capacities
X
X
X
12–20–00
Test run of
Chapter
Signa-
ture
cooling
system
Engine
cleaning
Fluid
engine
05–20–00
Page 15