Cleaning
To clean the dry filter the following steps are necessary:
Step
Figure 7.10: Cleaning the dry air filter
After cleaning
NOTE
Each filter pleat must be sprayed with oil.
After 5 to 10 min. the filter will be soaked with oil, noticeable by the uniform red coloring.
Figure 7.11: After cleaning
Effectivity: 912 i Series
Edition 2/Rev. 0
BRP-Rotax
MAINTENANCE MANUAL LINE
Procedure
1
Lightly tap and brush off surface dirt (A).
2
Spray K&N filter cleaner onto filter surface and leave to soak for approx. 10
min. (B).
3
Rinse air filter with low pressure water from inside to outside and let ele-
ment dry naturally (C).
A
Never use gear oil, diesel or engine oil, as they attract humidity.
B
ATTENTION
08865
C
08864