Module 9190 Starting The Operating Times; Module 9191 Stopping The Operating Times - HEIDENHAIN TNC 426 PB/M Technical Manual

Table of Contents

Advertisement

December 2001
MP7237
Displaying and resetting the operating times
Format:
%xxxxxxxx
MP7237.0
Displaying PLC operating times
Input:
Bits 0 to 7 represent PLC operating times 1 to 8
0: Do not display
1: Display
MP7237.1
Resetting PLC operating times with the code number 857282
Input:
Bits 0 to 7 represent PLC operating times 1 to 8
0: Do not reset
1: Reset
MP7237.2
Resetting NC operating times with the code number 857282
Input:
Bit 0 – No function
Bit 1 – "Machine on" operating time
Bit 2 – "Program run" operating time
0: Do not reset
1: Reset
MP7238.0-7 Dialog messages for PLC operating times 1 to 8
Input:
0 to 4095
Dialog no. from the file PLCDIALOG= (OEM.SYS)

Module 9190 Starting the operating times

You start one or more operating times.
Call:
PS
B/W/D/K <PLC operating time>
Bits 0 to 7 represent PLC operating times 1 to 8
CM
9190
Error recognition:
Marker
Value
Meaning
M4203
0
PLC operating time started
1
Incorrect parameter

Module 9191 Stopping the operating times

You stop one or more operating times.
Call:
PS
B/W/D/K <PLC operating time>
Bits 0 to 7 represent PLC operating times 1 to 8
CM
9191
Error recognition:
Marker
Value
Meaning
M4203
0
PLC operating time started
1
Incorrect parameter