Axis-Specific Dsp Error Messages With Error Code - HEIDENHAIN TNC 426 PB/M Technical Manual

Table of Contents

Advertisement

10.1.2 Axis-Specific DSP Error Messages with Error Code

Error message
DSP ERROR F010 y
DSP ERROR F020 y
DSP ERROR F030 y
DSP ERROR F040 y
DSP ERROR F050 y
DSP ERROR F060 y
DSP ERROR F070 y
DSP ERROR F080 y
DSP ERROR F090 y
DSP ERROR F0A0 y
DSP ERROR F0B0 y
DSP ERROR F0C0 y
DSP ERROR F0D0 y
DSP ERROR F0E0 y
DSP ERROR F0F0 y
DSP ERROR F100 y
DSP ERROR F110 y
DSP ERROR F120 y
DSP ERROR F130 y
DSP ERROR F140 y
DSP ERROR F150 y
DSP ERROR F160 y
DSP ERROR F170 y
DSP ERROR F180 y
DSP ERROR F190 y
DSP ERROR F1A0 y
DSP ERROR F1B0 y
DSP ERROR F1C0 y
DSP ERROR F200 y
DSP ERROR F210 y
DSP ERROR F220 y
DSP ERROR F230 y
DSP ERROR F240 y
December 2001
DSP Error Messages NC Software 280 470-xx, 280 472-xx, 280 474-xx
With the following error messages, in addition to the error code, the number
of the axis or spindle is output:
n
y = 0 to 8: Axes 1 to 9
n
y = 9 or F: Spindle
Cause of error, corrective action
Motor type unknown, MP2200 (error in motor table or
MP2200)
Reserved
Reserved
Number of pole pairs too large (error in motor table or
MP2230)
ASM: field-defining current (error in motor table)
Grating period of velocity encoder (error in motor table)
ASM: Rotor time constant (error in motor table)
Break/rated speed (error in motor table)
Unknown drive type, MP2000
Reserved
Reserved
Reserved
Current sensor voltage (error in power module table)
Peak current in power module (error in power module table)
Current controller proportional factor too high
Current controller integral factor too high
Motor temperature
Reserved
Oscilloscope parameter is incorrect. Only for test purposes
(data processing error)
Rated current of power module (error in power module)
Rated current of motor (error in motor table)
Peak current of motor (error in motor table)
Max. motor speed (error in motor table)
SM: wrong angle compensation values, MP2340, MP2350
Power module dc-link voltage incorrect
Invalid rotational speed input selected
Invalid PWM output
Band-pass parameter incorrect, MP2540, MP2550
Contamination of encoder Zn track, amplitude too small
Contamination of encoder Z1 track, amplitude too small
Reserved
Motor temperature too high
Unknown counter chip type at rotational speed input
(hardware problem)
As of
NC SW
280 470-01,
280 472-01,
to
280 474-03
10 – 5