HEIDENHAIN TNC 426 PB/M Technical Manual page 643

Table of Contents

Advertisement

December 2001
Module 9246 Writing to a field in a table
Open the table with the file name extension .TAB or .P with Module 9240, and
not in the "buffered" mode.
The field defined by the column name and line number is overwritten.
The module transfers a string.
Call:
PS
D
<File handle>
from Module 9240
PS
B/W/D/K <Line>
0 to 65 535
PS
B/W/D/K/S<String number, column name>
0 to 15
PS
B/W/D/K/S<String number, contents to be written>
0 to 15
CM
9246
Error recognition:
Marker
Value
Meaning
M4203
0
Field was written to
1
Error code in W1022
W1022
1
Line does not exist in table
2
Incorrect "file handle" or table was opened in
"buffered" mode
3
Impermissible string numbers
6
Table is write-protected
7
Not a numerical field (Module 9256)
11
The transferred value cannot be saved to the
addressed field. Incorrect format.
20
NCMACRO.SYS does not exist
29
The opened file is not a table (extension .TAB, .P)
30
Column name not found