HEIDENHAIN TNC 426 PB/M Technical Manual page 1108

Table of Contents

Advertisement

Error message
C013 PWM frequency
error
D000 DP RAM area
overlap
D100 Software error
E001 Status NR1/NR2
not equal
E002 Status NE1/NE2
not equal
E003 PLC module 9169
illegal
E006 Wrong RDY status
of spindle
E007 Wrong RDY status
of axes
E008 SRG speed too
high
E009 Incorrect gear
range
E00A Safe machine
parameter erroneous
E00B Cutout channels
test error
E00C Error in MP
transfer
December 2001
Cause
n
Entered PWM frequency
in MP2180 lies outside
the permissible input
range.
n
An internal software
error has occurred.
n
An internal software
error has occurred.
n
NR2 input incorrectly
connected.
n
Internal software error.
n
NE2 input incorrectly
connected.
n
Internal software error.
n
PLC Module 9169 in
safety-oriented software
(illegal).
n
Internal software error.
n
Cabling to inverter
defective.
n
Spindle not connected
(spindle release relay).
n
Inverter defective.
n
Cabling to inverter
defective.
n
No axis connected (axis
release relay).
n
Inverter defective.
n
Safe reduced rotational
velocity (SRG) was
exceeded.
n
No standstill in safe
controlled stop (SBH)
operating mode.
n
Internal software error.
n
CRC checksum does not
fit the entered safe MPs.
n
Machine key depressed
(ZT.HR, ZT.MB, MT
signal).
n
MP3210 or MP3510
incorrect.
n
Software error MCU.
DSP Error Messages as of NC Software 280 476-01
Corrective action
n
Inform your service agency.
• Check MP2180.
n
Inform your service agency.
• Check software version.
n
Inform your service agency.
• Check software version.
n
Inform your service agency.
• Check the wiring.
• Check software version.
n
Inform your service agency.
• Check the wiring.
• Check software version.
n
Inform your service agency.
• Check the PLC program.
• Check software version.
n
Inform your service agency.
• Check the inverter and
cabling.
n
Inform your service agency.
• Check the inverter and
cabling.
n
Inform your service agency.
n
Inform your service agency.
• Check software version.
n
Inform your service agency.
• Check the safe machine
parameters.
n
Inform your service agency.
• Check the wiring X65, X66
(, X67).
• Check the machine keys.
n
Inform your service agency.
• Check MP3210 and
MP3510.
• Check software version.
As of
NC SW
280 476-01
280 476-01
280 476-07
280 476-01
280 476-01
280 476-01
280 476-01
280 476-01
280 476-01
280 476-01
280 476-01
280 476-01
280 476-01