4.3.10 Digitizing with TS (option)
MP
Function and input
MP6200
Selection of triggering or measuring touch probe (only with
"digitizing with measuring touch probe" option)
Input:
MP6210
Number of oscillations in normal direction per second
Input:
MP6220
Traverse distance for lubrication of the touch probe axis at
line end
Input:
MP6221
Time after which the probe axis must be lubricated
Input:
MP6230
Feed rate in normal direction
Input:
MP6240
Maximum deflection of the stylus
Input:
MP6260
Output of M90 in NC blocks with digitized data
Input:
MP6270
Rounding of decimal places
Input:
December 2001
0: Triggering touch probe (e.g. TS 220)
1: Measuring touch probe
0 to 65.535 [1/s]
0 to 999.999 [mm]
0 to 65 535 [mm]
0 to 1 000 [mm/min]
0 to 10 000 [mm]
0: No output of M90
1: Output of M90 in every NC block
0: Output in 0.001-mm steps (1 µm)
0: Output in 0.01-mm steps (10 µm)
2: Output in 0.0001-mm steps (0.1 µm)
List of Machine Parameters
Software
Page
version and
behavior
PLC, CN123 6 – 346,
6 – 368
PLC, CN123
6 – 361
RUN
PLC, CN123
6 – 363
RUN
PLC, CN123
6 – 363
RUN
PLC, CN123
6 – 361
RUN
PLC, CN123
6 – 361
RUN
PLC, CN123
6 – 361
RUN
PLC, CN123
6 – 361
RUN
4 – 41