Error message
DSP ERROR C270 y
DSP ERROR C280 y
DSP ERROR C290 y
DSP ERROR C2A0 y
DSP ERROR C2B0 y
DSP ERROR C2C0 y
DSP ERROR C300 y
DSP ERROR C310 y
DSP ERROR C320 y
DSP ERROR C330 y
DSP ERROR C340 y
DSP ERROR C350 y
DSP ERROR C360 y
DSP ERROR C370 y
DSP ERROR C380 y
DSP ERROR C390 y
DSP ERROR C3A0 y
DSP ERROR C3B0 y
DSP ERROR C3C0 y
DSP ERROR C3D0 y
DSP ERROR C3E0 y
December 2001
DSP Error Messages NC Software 280 470-xx, 280 472-xx, 280 474-xx
Cause of error, corrective action
Max. motor speed (error in motor table)
SM: wrong angle compensation values, MP2340, MP2350
Power module dc-link voltage incorrect
Invalid rotational speed input selected
Invalid PWM output
Band-pass parameter incorrect, MP2540, MP2550
Contamination of encoder Zn track, amplitude too small
Contamination of encoder Z1 track, amplitude too small
Reserved
Motor temperature too high
Unknown counter chip type at rotational speed input
(hardware problem)
Power module switches off during operation (external
operation error)
Reserved
Excessive angular deviation during alignment, Zn/Z1 tracks
do not match (encoder error)
Motor is uncontrollable, at I
movement (drive error)
Error in 3-D probe/evaluation. No latching with L1 input
(G19/G26) (hardware problem)
Incorrect ref. position found (hardware problem)
Standstill detection (drive error)
Actual current of motor exceeds limit (drive error)
Status error in PWM chip (hardware problem)
Incorrect rated voltage of motor (error in motor table)
no expected rotary
max
As of
NC SW
280 474-04
10 – 7