H1 System Schematic - Danfoss H1B 060 Service Manual

H1 bent axis motors
Hide thumbs Also See for H1B 060:
Table of Contents

Advertisement

Service Manual
H1 Bent Axis Motors, Size 060/080/110/160/210/250 cm3
H1 general information

H1 system schematic

System schematic H1 pump and H1 motor with EDC
M14
C2
F00B
F00A
M5
M4
The schematic above shows the function of a hydrostatic transmission using an H1 axial variable displacement pump with electric
proportional displacement control (EDC) and an H1 bent axis variable displacement motor with electric proportional control (L*) and
integrated loop flushing device.
12 |
©
Danfoss | August 2018
M6
1
2
R1
C1
CW
S
L3 L4
max. 3 bar
[43.5 psi]
M3 L1
L2 MA
A
A
B
B
MB
L2
max.
min.
M4
M5
AX00000025en-US0504
MA
N
n
L1
MB
P003 424

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H1b 080H1b 160H1b 210H1b 250H1b 110