Service Manual
H1 Bent Axis Motors, Size 060/080/110/160/210/250 cm3
Minor repair
50 |
©
Danfoss | August 2018
6. Install and torque plug (C0050) to 40 N•m [30 lbf•ft] using a 1/4 inch internal hex wrench.
7. Install actuator (B0010) using a 4 mm internal hex wrench.
8. Install screws (B0050) with torque to 6 N•m [4 lbf•ft].
If replacing the hydraulic actuator, set the threshold pressure to the proper setting. Refer to
threshold on test stand
on page 36