Loop Flushing Relief Valve - Danfoss H1B 060 Service Manual

H1 bent axis motors
Hide thumbs Also See for H1B 060:
Table of Contents

Advertisement

Service Manual
H1 Bent Axis Motors, Size 060/080/110/160/210/250 cm3
Operation

Loop flushing relief valve

©
Danfoss | August 2018
The loop flushing relief valve is incorporated into all H1 motors and uses the loop flushing option in
installations that require fluid to be removed from the low pressure side of the system circuit due to
cooling requirements.
The loop flushing relief valve is also used to facilitate the removal of contaminants from the loop.
The loop flushing valve is equipped with an orificed charge pressure relief valve designed with a cracking
pressure of 16 bar [232 psi].
Valves are available with several orifice sizes to meet the flushing flow requirements of all system
operating conditions.
Loop flushing relief valve (cross section)
P003 491
Loop flushing relief valve sizes
5
10
15
40 bar
30 bar
20 bar
10 bar
0
10
20
X
X
Loop flushing flow (l/min)
Y
Low system pressure minus case pressure (bar)
Loop flushing relief valve schematic
A
B
P003 487
20
30
40
50
30
40
50
60
P006 034
L2
AX00000025en-US0504 | 21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H1b 080H1b 160H1b 210H1b 250H1b 110

Table of Contents