Loop Flushing Charge Relief Valve - Danfoss H1B 060 Service Manual

H1 bent axis motors
Hide thumbs Also See for H1B 060:
Table of Contents

Advertisement

Service Manual
H1 Bent Axis Motors, Size 060/080/110/160/210/250 cm3
Minor repair

Loop flushing charge relief valve

64 |
©
Danfoss | August 2018
Removal
1. Using a 24 mm hex wrench remove valve (L00**)
2. Remove and discard O-ring (L0050).
Do not disassemble valve. If you suspect malfunction, replace valve.
Assembly
1. Install new O-ring (L0050).
2. Using a 24 mm hex wrench, install valve (L00**). Torque to 67 N•m [49 lbf•ft].
Loop flushing charge relief valve replacement
L0050
L00**
24 mm
67 N•m [49 lbf•ft]
AX00000025en-US0504

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H1b 080H1b 160H1b 210H1b 250H1b 110