Required Tools And Standard Procedures - Danfoss H1B 060 Service Manual

H1 bent axis motors
Hide thumbs Also See for H1B 060:
Table of Contents

Advertisement

Service Manual
H1 Bent Axis Motors, Size 060/080/110/160/210/250 cm3

Required tools and standard procedures

Required tools
Standard procedures
©
Danfoss | August 2018
The service procedures described in this manual can be performed using common mechanic's hand
tools. Special tools, if required, are shown. When testing system pressures, calibrate pressure gauges
frequently to ensure accuracy. Use snubbers to protect gauges.
C
Caution
Contamination can damage internal components and void the manufacturer's warranty. Take
precautions to ensure system cleanliness when removing and reinstalling system lines
1. With the prime mover off, thoroughly clean all dirt and grime from the outside of the motor. Ensure
the surrounding areas are clean and free of contaminants such as dirt and grime.
2. If removing the motor, tag each hydraulic line connected to the motor. If you disconnect hydraulic
lines, plug each open port to keep dirt and contamination out of the motor.
3. Inspect the system for contamination. Look at the hydraulic fluid for signs of system contamination,
such as oil discoloration, foam in the oil, sludge, or small metal particles.
4. Remove the motor as a single unit.
C
Caution
Be careful not to damage solenoids and electrical connections when using straps or chains to remove
motor from machine.
5. Perform motor function test.
6. Before re-installing the motor on the machine, drain the system, flush all lines, replace all filters, and
fill with new hydraulic fluid.