Service Manual
H1 Bent Axis Motors, Size 060/080/110/160/210/250 cm3
H1 general information

General description

10 |
©
Danfoss | August 2018
Series H1 variable displacement motors are bent axis design, incorporating spherical pistons.
These motors are designed primarily to be combined with other products in closed circuit systems to
transfer and control hydraulic power. Series H1 motors have a large maximum/minimum displacement
ratio of 5:1 and high output speed capabilities.
The expanded function of zero degree capability, coupled with a high performance 32 degree maximum
angle, creates opportunities to easily improve the machine performance for:
Wheel assist on the steering axle of high inertia machines (i.e. combines) and could include Anti Slip
Control
Off-highway machines requiring Anti Slip Control (i.e. Ag. sprayer)
Multi-motor applications requiring optimized work and transport modes (i.e. wheel loader, Ag
sprayer) utilizing the zero degree position for maximum transport speed
Improved machine (i.e. single drum roller) gradeability through precise Anti Slip Control
The Anti Slip Control reduces ground damage, increases traction control and improves machine
controllability for the operator.
SAE, Cartridge (not available for 210 cm
radial or axial high pressure port configurations are available including the loop flushing device.
A complete family of controls and regulators are available to fulfill the requirements of a wide range of
applications.
Motors normally start at maximum displacement. This provides maximum starting torque for high
acceleration.
All controls utilize internally supplied servo pressure. This may be overridden by a pressure compensator
which functions when the motor is operating in motor and pump modes. A defeat option is available to
disable the pressure compensator override when the motor is running in pump mode during
deceleration/braking.
The pressure compensator option features a low pressure rise to ensure optimal power utilization
throughout the entire displacement range of the motor.
Speed sensor options are available to cover all frame sizes and flange styles.
They are capable of sensing the following, all in one package:
Speed
Direction (only group "J", option "S")
Temperature (only group "J", option "S")
The electric controls are specifically designed for the Danfoss family of PLUS+1
easy "Plug and Perform" installation.
3
3
and 250 cm
) and DIN (not available for 250 cm
3
) flange with
®
microcontrollers for
AX00000025en-US0504

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H1b 080H1b 160H1b 210H1b 250H1b 110

Table of Contents