Adjustments - Danfoss H1B 060 Service Manual

H1 bent axis motors
Hide thumbs Also See for H1B 060:
Table of Contents

Advertisement

Service Manual
H1 Bent Axis Motors, Size 060/080/110/160/210/250 cm3

Adjustments

Adjusting the minimum displacement limiter
34 |
©
Danfoss | August 2018
Minimum displacement limiter
19 mm
45 N•m
[32 lb•ft]
N0020
1. Remove cap (N0120).
Removing the cap destroys the caps locking mechanism. Replace with a new cap.
2. Using a 6 mm internal hex wrench, hold adjusting screw (N0010) in place.
3. Using a 19 mm hex wrench, loosen seal locknut (N0020).
4. Turn adjusting screw clockwise to increase minimum displacement or counterclockwise to decrease
minimum displacement.
Minimum displacement is inversely related to maximum shaft speed. To increase maximum speed,
decrease minimum displacement. Adjusting displacement limits also affects output torque. Refer to
the table below for displacement change per turn.
Displacement change per turn
Size
060
3
2.1 cm
Displacement
3
[0.13 in
change
5. When properly adjusted, hold adjusting screw in place and torque seal lock-nut to 45 N•m [32 lbf•ft].
6. With motor on machine or test stand, verify correct motor function. Refer to
Information
on page 26 for location of gauge ports and suggested gauge sizes.
7. Install new cap (N0120).
N0010
6 mm
N0120
080
110
3
3
2.6 cm
3.2 cm
3
3
]
[0.16 in
]
[0.20 in
]
160
210
250
3
3
4.1cm
5.1 cm
5.5 cm
3
3
[0.25 in
]
[0.31 in
]
[0.34 in
Ports and Gauge